www.strongtie.com


ICFVL Ledger Connector System

  Print this page
Link to email this page to a friend  Email this page to a friend

The ICFVL Ledger Connector System is engineered to solve the challenges of mounting wood or steel ledgers to insulated concrete form (ICF) walls. The ICFVL is designed to provide both vertical and lateral, in-plane performance. There are many benefits over traditional anchor bolting, including better on center spacing in most cases, faster installation and no protrusions.

The embedded legs of the ICFVL are embossed for additional stiffness and the hole allows for concrete to flow through and around the connector. The exposed flange on the face of the ICF provides a structural surface for mounting either a wood or steel ledger.

Material: ICFVL - 68 mil (14 ga)

Finish: Galvanized.

Installation: ICFVL in ICF

CFS Ledger Attachment

WARNING: Industry studies show that hardened fasteners can experience performance problems in wet environments.
Accordingly, use this product in dry environments only.

top Gallery:
  roll over images below to see larger image
 
ICFVL
Patent Pending
ICFVL
Typical CFS Ledger Installation with ICFVL
(minimum 54 mil)
Requires 4 screws at each location.
Table provides on center spacing.


top Load Tables:See code report listings below
These tables address vertical load applications only.
Table
  1. Fasteners for CFS ledger are not provided.
  2. Loads apply to ICF foam thicknesses of 2 3/4" or less. Contact Simpson for allowable loads on thicker walls.
  3. Alternately, #14 x 3/4" fastener may be used.
  4. Tabulated loads are governed by tests and may not be increased. Refer to Steel Stress Increase for additional information.
  5. Concrete f'c = 2500 psi minimum.
  6. When combining download and lateral loads, Designer shall evaluate as follows:
       Design Download/Allowable Download + Design Lateral Load/Allowable Lateral Load ≤ 1.

These tables address vertical load applications only.
Table
  1. The Designer may specify different spacing based on the load requirements.
  2. See flier F-ICFVL for additional connection details.
  3. CFS ledger values are based on steel. Fu = 65 ksi.

top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
ICFVL      FL6482      

   
top
Drawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
DWG
Orthographic DXF
Orthographic top
Order free catalogs by mail
top top
Fliers (PDFs):
top

Home | About Simpson | Contact Simpson | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson's newsletters

Copyright © 2008, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2008 Simpson Strong-Tie®