www.strongtie.com


EDOT Epoxy Anchoring Adhesive

EDOT adhesive is formulated to provide an economical and high-strength solution for transportation projects.* It is a two component, high-solids epoxy-based system that is a non-shrink anchor grouting material. Resin and hardener are dispensed and mixed simultaneously through the static mixing nozzle. EDOT meets the requirements of ASTM C-881 and AASHTO M235 specifications for Type I, II, IV and V, Grade 3, Class C.

*Visit www.strongtie.com/dot for specific state DOT approvals.

GALLERY: roll over images below to see larger image

EDOT22

EDOT56

EDOT 1 gallon kit


EDOT 10 gallon kit

EMN22i

EDTA22P


USES

  • Threaded rod anchoring
  • Rebar doweling

APPLICATION

Surfaces to receive epoxy must be clean. The base material temperature must be 40ºF or above at the time of installation. For best results, material should be 70ºF–80ºF at the time of application. Cartridges should not be immersed in water to facilitate warming. To warm cold material, the cartridges should be stored in warm, uniformly heated area or storage container for a sufficient time to allow epoxy to warm completely. Mixed material in nozzle can harden in 5-7 minutes at a temperature of 40ºF or above.

INSTALLATION

IMPORTANT For installation instructions, click here.

TEST CRITERIA

Anchors installed with EDOT adhesive have been tested in accordance with ASTM E488 and ASTM E1512.

PROPERTY TEST METHOD RESULTS
 Consistency (77ºF)    ASTM C-881    Non-sag/ thixotropic paste  
 Heat deflection    ASTM D-648    129ºF (54ºC)  
 Bond strength (moist cure)    ASTM C-882    3054 psi (2 days) 3425 psi (14 days)  
 Water absorption    ASTM D-570    0.04% (24 hours)  
 Compressive yield strength    ASTM D-695    10,053 psi (7 days)  
 Compressive modulus    ASTM D-695    393,000 psi (7 days)  
 Gel time    ASTM C-881    46 min. @ 73 ºF (23ºC) 32 min. @ 90 ºF (32ºC)  

STORAGE CONDITIONS

For best results, store between 45ºF–90ºF. To store partially used cartridges, leave hardened nozzle in place. To re-use, attach new nozzle.

CHEMICAL RESISTANCE

Very good to excellent against distilled water, dilute inorganic acids and alkalis. Fair to good against organic acids and alkalis, and many organic solvents. Poor against ketones. For more detailed information, see Technical Bulletin T-SAS-CHEMRES or contact Simpson Strong-Tie.

ET glamour

ACCESSORIES / RELATED PRODUCTS

View dispensing tools, mixing nozzles and other accessories.

SUGGESTED SPECIFICATIONS

Anchoring adhesives shall be a twocomponent high solids epoxy based system dispensed through a static mixing nozzle supplied by the manufacturer. Epoxy shall meet the minimum requirements of ASTM C881 and AASHTO M235 specification for Type I, II, IV, and V, Grade 3, Class C, and must develop a minimum 10,000 psi compressive yield strength after 7 day cure. Epoxy must have a heat deflection temperature of a minimum 125ºF (52ºC). Adhesive shall be EDOT adhesive from Simpson Strong-Tie, Pleasanton, CA. Anchors shall be installed per Simpson Strong-Tie instructions for EDOT adhesive.

SHELF LIFE

24 months from date of manufacture in unopened container.

COLOR

Resin – white, hardener – brown When properly mixed, EDOT adhesive will be a uniform and consistent tan color.

CLEAN UP

Uncured material – Wipe up with cotton cloths. If desired, scrub area with abrasive, waterbased cleaner and flush with water. If approved, solvents such as ketones (MEK, acetone, etc.), lacquer thinner, or adhesive remover can be used. DO NOT USE SOLVENTS TO CLEAN ADHESIVE FROM SKIN. Take appropriate precautions when handling flammable solvents. Solvents may damage surfaces to which they are applied. Cured material – Chip or grind off surface.

 
 
 
EDOT Package Systems
  1. Cartridge and bulk estimation guides are available.
  2. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available here.
  3. Use only appropriate Simpson Strong-Tie® mixing nozzle in accordance with Simpson Strong-Tie instructions. Modification or improper use of mixing nozzle may impair epoxy performance.
  4. Metering pumps offered by third-party manufacturers.
In-Service Temperature
Sensitivity
Cure Schedule
Pot Life for 1 Gallon
Mixed
go to top of page
Printed from
© 2013 Simpson Strong-Tie Company Inc.