ET-HP™ (formerly ET) Anchoring Adhesive
Tension Loads for Threaded Rod
and Rebar in Normal-Weight Concrete
- Allowable load must be the lesser of the bond or steel strength.
- The allowable loads listed under allowable bond are based on a safety factor of 4.0.
- Refer to allowable load-adjustment factors for spacing and edge distance.
- Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature.
- Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
- Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fireexposure and elevated-temperature conditions.