SET High Strength Epoxy-Tie® Anchoring Adhesive
Tension Loads for Threaded Rod Anchors in Normal-Weight Concrete Stemwall
- Allowable load must be the lesser of the bond or steel strength.
- The allowable loads listed under allowable bond are based on a safety factor of 4.0.
- Allowable loads may be increased by 33 1/3 percent for short-term loading due to wind or seismic forces where permitted by code.
- Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature.
- Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
Edge and end distances for threaded rod in concrete foundation stemwall corner installation