SET-XP® Structural Epoxy-Tie Anchoring Adhesive

Tension Design Data for Threaded Rod and

Rebar in Normal-Weight Concrete1,12

Information on this page has been updated since the printing of the 2009-2010 Anchor Systems Catalog.
To view the specific changes made to this page in detail, see Catalog Changes and Corrections.
Tension Load Threaded Rod Rebar Concrete

Strong-Bolt Characteristic Shear Design Values

  1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modified below.
  2. Temperature Range 1: Maximum short-term temperature of 110°F (43°C). Maximum long-term temperature of 75°F (24°C).
  3. Temperature Range 2: Maximum short-term temperature of 150°F (66°C). Maximum long-term temperature of 110°F (43°C).
  4. Short-term concrete temperatures are those that occur over short intervals (diurnal cycling).
  5. Long-term concrete temperature are constant temperatures over a significant time period.
  6. For anchors that only resist wind or seismic loads, bond strengths may be increased by 72%.
  7. In water-saturated concrete, multiply τk,uncr and τk,cr by Ksat.
  8. For anchors installed in overhead and subjected to tension resulting from sustained loading, multiply the value calculated for Na according to ICC-ES AC308 by 0.75. .
  9. The value of phi applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer toSection D.4.5 to determine the appropriate value of phi.
  10. The value of phi applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements ofSection D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer toSection D.4.5 to determine the appropriate value of phi.
  11. The value of phi applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements ofSection D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements ofSection D.4.4(c) for Condition A are met, refer toSection D.4.4 to determine the appropriate value of phi. If the load combinations of ACI 318 Appendix C are used, refer toSection D.4.5 to determine the appropriate value of phi.
  12. Sand-lightweight and all-lightweight concrete are beyond the scope of this table.
  13. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, the bond strength values for 7/8" anchors or #7 rebar anchors must be multiplied by αN,seis = 0.80.
  14. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, the bond strength values for 1" anchors or #8 rebar anchors must be multiplied by αN,seis = 0.92
  15. The values of f'c used for calculation purposes must not exceed 8,000 psi (55.1 MPa) for uncracked concrete. The value of f'c used for calculation purposes must not exceed 2500 psi (17.2 MPa) for cracked concrete.

 

 

Home | About Simpson Strong-Tie | Contact Simpson Strong-Tie | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson Strong-Tie newsletters

Copyright © 2012, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2012 Simpson Strong-Tie®