Titen HD® Mini Screw Anchor for Concrete and Masonry
Tension and Shear Loads
Tension Loads in Normal-Weight Concrete
- The allowable loads are based on a safety factor of 4.0.
- The minimum concrete thickness is 1 1/2 times the embedment depth.
- Tension and Shear loads may be combined using the straight line interaction equation (n=1).
Shear Loads in Normal-Weight Concrete
- The allowable loads are based on a safety factor of 4.0.
- The minimum concrete thickness is 1 1/2 times the embedment depth.
- Tension and Shear loads may be combined using the straight line interaction equation (n=1).
Tension and Shear Loads in 8-inch Lightweight, Medium-Weight and Normal-Weight Hollow CMU
- The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC.
- Values for 8-inch wide, lightweight, medium-weight, and normal-weight CMU.
- The minimum specified compressive strength of masonry, f'c, at 28 days is 1,500 psi.
- Embedment depth is measured from the outside face of the concrete masonry unit and is based on the anchor being embedded an additional 1/4" through the 1 1/4" thick face shell.
- Allowable loads may not be increased for short-term loading due to wind or seismic forces. CMU wall design must satisfy applicable design standards and be capable of withstanding applied loads.
- Set drill to rotation-only mode when drilling into hollow CMU.
- Do not use impact wrenches to install in hollow CMU.