Tension Loads in Normal-Weight Concrete Stemwall
-
Allowable load must be the lesser of the concrete or steel strength.
Edge and end distances for Titen HD rod coupler in concrete foundation stemwall corner installation
- The allowable loads based on concrete strength are based on a factor of safety of 4.0.
- The allowable load based on steel strength is limited by the strength of the coupler nut supplied with this anchor. Use of higher strength rod will not increase allowable loads.
- The minimum concrete thickness is 1.5 times the embedment depth.
- Tension and shear loads may be combined using the straight-line interaction equation (n=1).
Shear Loads in Normal-Weight Concrete Stemwall,
Load Applied Parallel to Concrete Edge
- Install with a washer (not supplied with anchor) when used to resist shear loads.
- The allowable load based on concrete edge distance is based on a factor of safety of 4.0. Steel strength does not control.
- The minimum concrete thickness is 1.5 times the embedment depth.
- Tension and shear loads may be combined using the straight-line interaction equation (n=1).