Wedge-All® Wedge Anchors

Load-Adjustment Factors

for Carbon-Steel and Stainless-Steel Wedge-All® Anchors

in Normal-Weight Concrete: Spacing, Shear Loads

 

How to use these charts:

  1. The following tables are for reduced spacing.
  2. Locate the anchor size to be used for a shear load application.
  3. Locate the anchor embedment (E) used for a shear load application.
  4. Locate the edge spacing (Sact) at which the anchor is to be installed.
  5. The load-adjustment factor (fs) is the intersection of the row and column.
  6. Multiply the allowable load by the applicable load-adjustment factor(s).
  7. Reduction factors for multiple spacings are multiplied together.
Shear Load Normal Weight Concrete Spacing
Spacing Shear (fs)
Edge Distance Shear See Notes Below

Edge Distance Shear
 
  1. E = embedment depth (inches).
  2. Sact = actual spacing distance at which anchors are installed (inches).
  3. Scr = critical spacing distance for 100% load (inches).
  4. Smin = minimum spacing distance for reduced load (inches).
  5. fs = adjustment factor for allowable load at actual spacing distance.
  6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00.
  7. fsmin = adjustment factor for allowable load at minimum spacing distance.
  8. fs = fsmin + [(1-fsmin) (Sact - Smin) / (Scr - Smin)].
 

Home | About Simpson Strong-Tie | Contact Simpson Strong-Tie | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson Strong-Tie newsletters

Copyright © 2012, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2012 Simpson Strong-Tie®