www.strongtie.com


USA / Canada | Change Location...

PDPA Series Fasteners

Tension and Shear Loads in Steel

 
Tension Load Shear Load Steel
PDP Series Fasteners - Tension and Shear Loads in Steel
PDP Series Fasteners - Tension and Shear Loads in Steel
  1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values, unless otherwise indicated in footnote 4, 5, 6 or 7.
  2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria.
  3. Steel strength must comply with the minimum requirements of ASTM A 36 (Fy = 36 ksi, Fu = 58 ksi) or ASTM A 572, Grade 50 (Fy = 50 ksi, Fu = 65 ksi), or ASTM A992 (Fy = 50 ksi, Fu = 65 ksi).
  4. Based upon minimum penetration depth of 0.46" (11.7 mm).
  5. Based upon minimum penetration depth of 0.58" (14.7 mm).
  6. Based upon minimum penetration depth of 0.36" (9.1 mm).
  7. The fastener must be driven to where the point of the fastener penetrates through the steel.
PDP

PDPA
click on the link above for more information on these fasteners

 

Home | About Simpson Strong-Tie | Contact Simpson Strong-Tie | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson Strong-Tie newsletters

Copyright © 2012, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from