www.strongtie.com


>>Home   > All Products - Alphabetical List

HDA/HD Holdowns

  Print this page
Link to email this page to a friend  Email this page to a friend

All HDAs and the HD15 are self-jigging, ensuring code-required minimum 7 bolt diameter spacing from the end of the wood member to the center of the first bolt hole per NDS-2005 Section 11.5.1.

HD6A, HD8A, HD10A and HD14A's seat design allows greater installation adjustability. An overall width of 3 1/4" for the HD6A, HD8A and HD10A, and 3 1/2" for the HD14A provides an easy fit in a standard 2x4 stud wall.

HDA/HD Special Features:

Material: See table.

Finish: HD14A and HD15 - Simpson gray paint. Other HDA's - galvanized. May be ordered HDG; contact Simpson.

Installation:

For holdowns, per ASTM test standards, anchor bolt nuts should be finger-tight plus 1/3 to 1/2 turn with a hand wrench, with consideration given to possible future wood shrinkage. Care should be taken to not over-torque the nut. Impact wrenches should not be used.

top Gallery:
  roll over images below to see larger image
 
HD10A
(HD6A, HD8A and HD14A similar)
HD5A
(HD2A similar)
Vertical HD5A Installation with SSTB anchor bolt.
Washers are not required at the base.
 

Typical HD5A Tie Between Floors

*To achieve table loads, the minimum bolt end distance is seven bolt diameters. This distance is designed into holdowns.

BP's are required by the City of Los Angeles. Check with your local building code on usage. (2005 NDS Section 11.1.2.3 requires a metal plate, metal strap, or minimum of a standard cut washer.)

HD2A installed as a lateral anchor for a deck guardrail post. Refer to technical bulletin T-HD2AGRDRL for more information.

Vertical HD15 Installation

 

top Load Tables:See code report listings below

Table
  1. See notes below
HD, HDA, HD2A, HD5A, HD6A, HD8A, HD10A, HD14A, HD15
  1. Allowable loads have been increased for earthquake or wind load duration wth no further increase allowed; reduce where other load durations govern.
  2. HD15 requires a minimum 4x8 (in a 3 1/2" wide shearwall) or a 6x6 nominal post. To ensure the tension load carrying capacity of the critical net section meets the holdown capacity.
  3. Use a minimum 4x6 nominal post for the HD14A. Minimum post size is required to ensure the tension load carrying capacity of the critical net section meets the holdown capacity.
  4. HB is the required minimum distance from the end of the stud to the center of the first stud bolt hole. End distance may be increased as necessary for installation.
  5. The designer must specify anchor bolt type, length and embedment. See SSTB Anchor Bolts and Additional Anchor Designs.
  6. Refer to technical bulletin T-ANCHORSPEC for retrofit anchorage solutions.
  7. Lag bolts will not develop the listed loads.
  8. See Product Use Information.
  9. Deflection at Highest Allowable Tension Load includes holdown elongation and anchor bolt elongation (L = 5"). Additional elongation of anchor bolts longer than 5" shall be added to holdown deflection.
  10. Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers. Values in the tables reflect installation into the wide face.
  11. To achieve published loads, machine bolts shall be installed with the nut on the opposite side of the holdown (see picture). If reversed, the Designer shall reduce the allowable loads shown per NDS requirements when bolt threads are in the shear plane.
  12. HDA and HD allowable loads are based on the lower of the 2005 NDS fastener values or the ultimate load on a steel test jig divided by 2.5.
  13. Post design shall be by Designer.
  14. Holdowns may be raised off sill plate. Refer to table for increased deflection values (if applicable). Refer to note q, General Instructions for the Installer for installation instructions of raised holdowns.

top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
HDSee specific model numbers for code listings.
HD10A    RR25528 FL503   ER-5708  
HD14A    RR25528 FL503   ER-5708  
HD15    RR25528 FL503   ER-5708  
HD2A    RR25528 FL503   ER-5708  
HD5A    RR25528 FL503   ER-5708  
HD6A    RR25528 FL503   ER-5708  
HD8A    RR25528 FL503   ER-5708  
HDASee specific model numbers for code listings.

   
top
Drawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
DWG
Perspective Orthographic DXF
Perspective Orthographic top
Order free catalogs by mail
top top top top
Fliers (PDFs):
top top

Home | About Simpson | Contact Simpson | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson's newsletters

Copyright © 2008, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2008 Simpson Strong-Tie®