
HU/HUC/HUCQ/HGUS
Glulam Beam and Double Shear Joist Hangers
See Hanger Options for hanger modifications, which may result in reduced loads.
HU/HUC - Most models have triangle and round holes. To achieve maximum loads, fill both round and triangle holes with common nails.
HGUS - Face mount hanger used for high load applications. All hangers in this series have double shear nailing. This patented innovation distributes the load through two points on each joist nail for greater strength. It also allows the use of fewer nails, faster installation, and the use of common nails for all connections. (Do not bend or remove tabs)
Material: See tables.
Finish: Galvanized. Some products available in ZMAX® coating; see Corrosion Information.
Installation:
Projection seat on most models for maximum bearing and section economy.
See Hanger Options for hanger modifications
| Legacy Reports | |||||||
| IAPMO ES ER | ICC-ES ESR | CITY OF LOS ANGELES | STATE OF FLORIDA | ICC-ES NER | ICC-ES ER | ICC-ES ES | |
| HGUS3.25/10 | FL11468 | ||||||
| HGUS3.25/12 | FL11468 | ||||||
| HGUS5.25/10 | FL11468 | ||||||
| HGUS5.25/12 | FL11468 | ||||||
| HGUS6.88/10 | FL11468 | ||||||
| HGUS6.88/12 | FL11468 | ||||||
| HGUS6.88/14 | FL11468 | ||||||
| HU210-2 | ESR-2549 / ESR-2523 * | RR25807 | FL10655 | ||||
| HU212-2 | ESR-2549 / ESR-2523 * | RR25807 | FL10655 | ||||
| HU216-2 | ESR-2549 / ESR-2523 * | RR25807 | FL10655 | ||||
| HU3.25/10.5 | ESR-2552 / ESR-2523 * | ||||||
| HU3.25/12 | ESR-2552 / ESR-2523 * | ||||||
| HU310-2 | ESR-2549 / ESR-2552 / ESR-2523 * | RR25801 / RR25807 | FL10655 / FL10531 | ||||
| HU5.125/12 | ESR-2552 / ESR-2523 * | ||||||
| HU5.125/13.5 | ESR-2552 / ESR-2523 * | ||||||
| HU5.125/16 | ESR-2552 / ESR-2523 * | ||||||
| HUC210-2 | ESR-2549 / ESR-2523 * | FL10655 | |||||
| HUC212-2 | ESR-2549 / ESR-2523 * | FL10655 | |||||
| HUC216-2 | ESR-2549 / ESR-2523 * | FL10655 | |||||
| HUC3.25/10.5 | ESR-2552 / ESR-2523 * | ||||||
| HUC3.25/12 | ESR-2552 / ESR-2523 * | ||||||
| HUC310-2 | ESR-2549 / ESR-2552 / ESR-2523 * | RR25801 | FL10655 / FL10531 | ||||
| HUC5.125/12 | ESR-2552 / ESR-2523 * | ||||||
| HUC5.125/13.5 | ESR-2552 / ESR-2523 * | ||||||
| HUC5.125/16 | ESR-2552 / ESR-2523 * | ||||||
| HUCQ5.25/11-SDS | FL11468 | ||||||
| HUCQ5.25/9-SDS | FL11468 | ||||||
| ORTHOGRAPHIC | PERSPECTIVE | |
| HGUS3.25/10 |
HGUS3.25/10: DWG | DXF
HGUS3.25/10 front view: DWG | DXF HGUS3.25/10 left view: DWG | DXF HGUS3.25/10 right view: DWG | DXF HGUS3.25/10 top view: DWG | DXF |
None for this model |
| HGUS3.25/12 |
HGUS3.25/12: DWG | DXF
HGUS3.25/12 front view: DWG | DXF HGUS3.25/12 right view: DWG | DXF HGUS3.25/12 top view: DWG | DXF |
None for this model |
| HGUS5.25/10 |
HGUS5.25/10: DWG | DXF
HGUS5.25/10 front view: DWG | DXF HGUS5.25/10 left view: DWG | DXF HGUS5.25/10 right view: DWG | DXF HGUS5.25/10 top view: DWG | DXF |
None for this model |
| HGUS5.25/12 |
HGUS5.25/12: DWG | DXF
HGUS5.25/12 front view: DWG | DXF HGUS5.25/12 left view: DWG | DXF HGUS5.25/12 right view: DWG | DXF HGUS5.25/12 top view: DWG | DXF |
None for this model |
| HGUS6.88/10 | None for this model | None for this model |
| HGUS6.88/12 | None for this model | None for this model |
| HGUS6.88/14 | None for this model | None for this model |
| HU210-2 |
HU210-2: DWG | DXF
HU210-2 with top flange: DWG | DXF HU210-2TFSKL: DWG | DXF HU210-2TFSKR: DWG | DXF HU210-2 front view: DWG | DXF HU210-2 with top flange front view: DWG | DXF HU210-2TFSKL front view: DWG | DXF HU210-2TFSKR front view: DWG | DXF HU210-2 left view: DWG | DXF HU210-2 with top flange left view: DWG | DXF HU210-2TFSKR left view: DWG | DXF HU210-2 right view: DWG | DXF HU210-2 with top flange right view: DWG | DXF HU210-2TFSKL right view: DWG | DXF HU210-2 top view: DWG | DXF HU210-2 with top flange top view: DWG | DXF HU210-2TFSKL top view: DWG | DXF HU210-2TFSKR top view: DWG | DXF |
None for this model |
| HU212-2 |
HU212-2: DWG | DXF
HU212-2 with top flange: DWG | DXF HU212-2 front view: DWG | DXF HU212-2 with top flange front view: DWG | DXF HU212-2 left view: DWG | DXF HU212-2 right view: DWG | DXF HU212-2 with top flange right view: DWG | DXF HU212-2 top view: DWG | DXF HU212-2 with top flange top view: DWG | DXF |
None for this model |
| HU216-2 | None for this model | None for this model |
| HU3.25/10.5 | None for this model | None for this model |
| HU3.25/12 | None for this model | None for this model |
| HU310-2 |
HU310-2: DWG | DXF
HU310-2 front view: DWG | DXF HU310-2 left view: DWG | DXF HU310-2 right view: DWG | DXF HU310-2 top view: DWG | DXF |
None for this model |
| HU5.125/12 | None for this model | None for this model |
| HU5.125/13.5 | None for this model | None for this model |
| HU5.125/16 | None for this model | None for this model |
| HUC210-2 |
HUC210-2: DWG | DXF
HUC210-2SKL: DWG | DXF HUC210-2SKR: DWG | DXF HUC210-2 front view: DWG | DXF HUC210-2SKL front view: DWG | DXF HUC210-2SKR front view: DWG | DXF HUC210-2 left view: DWG | DXF HUC210-2SKR left view: DWG | DXF HUC210-2 right view: DWG | DXF HUC210-2SKL right view: DWG | DXF HUC210-2 top view: DWG | DXF HUC210-2SKL top view: DWG | DXF HUC210-2SKR top view: DWG | DXF |
High Wind-Resistant Construction D108: Hanger Uplift Considerations: DWG
| DXF
|
| HUC212-2 | None for this model | None for this model |
| HUC216-2 | None for this model | None for this model |
| HUC3.25/10.5 | None for this model | None for this model |
| HUC3.25/12 | None for this model | None for this model |
| HUC310-2 | None for this model | None for this model |
| HUC5.125/12 | None for this model | None for this model |
| HUC5.125/13.5 | None for this model | None for this model |
| HUC5.125/16 | None for this model | None for this model |
| HUCQ5.25/11-SDS | None for this model | None for this model |
| HUCQ5.25/9-SDS | None for this model | None for this model |
|
|||