Mudsill anchor provide an alternative to anchor bolts. They easily mount on forms and make finishing easier. The unique design provides installation flexibility, eliminating problems with misplaced anchor bolts. Suitable for stem wall or slab foundations, mudsill anchors are one piece so there are no more nuts and washers to lose.

LMAZ - an economical replacement for 1/2" sill plate anchor bolts

MA - for slab or stem wall construction

MAB - anchors mudsill to concrete block, poured walls or slab foundations

Material: LMAZ, MAB - 18 gauge; MA - 16 gauge

Finish: MA, MAB - Galvanized (some available in ZMAX® finish)
LMAZ - ZMAX® only. See Corrosion Information.

Installation:



top Gallery:
  roll over images below to see larger image
 
LMA4Z
(LMA6Z similar)
MA4 and MA6 MAB Typical LMA/MA
Installation
(in concrete with framing)
 
MAB Misinstallation
(MAB straps must be
separated before the
concrete is poured)
Typical MAB23
Installation in Concrete Block
(MAB15 similar) MAB23 provides a two block embedment, if required by the local code jurisdiction
Typical MAB15
Installation in Concrete
(MAB23 similar, with 15" minimum embedment) Not applicable for concrete block installation
 

top Load Table:See code report listings below

Table
  1. Loads have been increased for short-term loading.
  2. For uplift loads, provide attachment from mudsill to building’s structural components to prevent cross-grain bending.
  3. MA installed attached to the stud has a perpendicular load of 670 lbs. Parallel loads as listed. For reduced uplift loads, contact Simpson.
  4. LMAZ installed attached to the stud has no load reduction for parallel andperpendicular loads. For reduced uplift contact Simpson.
  5. For stemwall applications, allowable loads are based on a minimum stemwall width of 6".
  6. NAILS: 10dx1 1/2" = 0.148" long . See other nail sizes and information.

top Prescriptive Anchor Spacing:

Table
  1. Place anchors not more than 1' from the end of each sill per code.
  2. Spacing is based on parallel to plate load direction only.
  3. CMU shall have a minimum f'm = 1500 psi and concrete shall have a minimum f'c = 2000 psi.
  4. Spacing applies to DF, SP, and HF 2x sill plates.
top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
LMA No code listing. Please contact us for test data.
LMA4ZNo code listing: Please contact us for test data.
LMA6ZNo code listing: Please contact us for test data.
LMAZSee specific model numbers for code listings.
MASee specific model numbers for code listings.
MA4    RR25149 FL474 NER-443    
MA6    RR25149 FL474 NER-443    
MABSee specific model numbers for code listings.
MAB15      FL474 NER-393 ER-5708  
MAB15Z      FL474 NER-393 ER-5708  
MAB23      FL474 NER-393 ER-5708  
MAB23Z      FL474 NER-393 ER-5708  
MABZ No code listing. Please contact us for test data.

   
top
Drawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
DWG
Perspective Orthographic DXF
Perspective Orthographic top
Order free catalogs by mail
top top top
Fliers (PDFs):
top

Home | About Simpson | Contact Simpson | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson's newsletters

Copyright © 2008, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2008 Simpson Strong-Tie®