LSTHD/STHD Strap Tie Holdown

  Print this page
Link to email this page to a friend  Email this page to a friend

Installation

View step-by-step installation instructions

The STHD is an embedded strap tie holdown with high load capacity and a staggered nail pattern to help minimize splitting. The STHD strap tie holdown incorporates many features that improve installation and function. When used in conjunction with the StrapMate® you have a system that prevents both parallel and perpendicular movement during installation relative to the form. Allows for accurate location of the STHDs and reduces the possibility of spalling.

Features

Material: LSTHD8, LSTHD8RJ - 14 ga, all others - 12 ga.

Finish: Galvanized

Installation:


top Gallery:
  roll over images below to see larger image
 
 
STHD
U.S. Patent 5,813,182
Nails are countersunk for a low profile strap surface.  

Typical STHD Applications
(for two pour, see footnote 5.)

Typical STHD14RJ Rim Joist Application Typical STHD14 End Installation
(No corner return)
Single Pour Rebar Installation Two Pour Rebar Installation
*Maintain minimum rebar cover, per ACI-318 concrete code requirements.
top Spall Reduction System for STHD Strap Tie Holdown:
 
 
SM1
U.S. Patent 6,796,099
Features and Benefits
  • Built-in Tab:
    • Reduces spalling and costly retrofits.
    • No additional labor to install.
    • Holds STHD away from form board.
  • StrapMate Locator Line:
    • Easy inspection to ensure proper location.
    • Allows Adjustment without removing STHD.
  • Additional Diamond Hole in RJ versions:
    • One more fastener to help prevent the STHD RJ models from bowing out at the rim joist section.

top Tension Loads for STHD Installations:See code report listings below
Table
  1. 'RJ' after the model indicates STHDs for rim joist applications, e.g. STHD8RJ.
  2. STHD14RJ on 8" stemwall requires 30-16d sinkers.
  3. 10d commons nails may be used with no load reduction.
  4. Minimum nail end distance to prevent splitting is 10 x diameter, 1 1/2" for 16d sinkers and 10d common.
  5. For two pour with 4" slab or less. The STHD14 load at 1/2" end distance 2000 psi is 3235 lbs. and 4220 lbs. at 14" end distance. The STHD10 at the same condition is 2035 lbs. for 1/2" end distance, and 2750 lbs. at 10" end distance.
  6. Allowable loads have been increased for wind or earthquake load durations with no further increase allowed; reduce where other load durations govern.
  7. Where fewer fasteners are used in the structural wood member, reduce loads according to the code.
  8. To get the full table load, the minimum center-to-center spacing is twice the embedment depth when resisting tension loads at the same time.
  9. There is an increase in the amount of deflection if the strap is installed on the outside of the shear panel instead of directly to the framing. Refer to technical bulletin T-PLYWOOD.
  10. Calculate loads using straight line interpolation for corner distances between 1/2" and le.
  11. STHD14RJ installed on HF/SPF in an 8" stemwall: the le load is 5370 lbs.
  12. Post design shall be by Designer.
  13. Loads shown apply to post tension slabs when one #4 rebar (minimum) is installed as in detail 1.
  14. Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers. Values in the tables reflect installation into the wide face. See technical bulletin T-SCLCOLUMN for values on the narrow face (edge).
  15. For concrete spalls between 1" and 4" the allowable loads is 0.90 of the table loads.
  16. Table loads apply to corner stemwall applications provided that there is a perpendicular stemwall at the corner having a minimum length of le. See tables for loads where there is not a perpendicular stemwall at corners.
  17. Testing to new ICC-ES acceptance criteria to be completed in 2009. Reference this web site for the latest loads and information.
  18. NAILS: 16d sinker = 0.148" dia. x 3 1/4" long. See other nail sizes and information.
top Load Table:
Table
  1. Loads based on 2500 psi minimum concrete strength
  2. Allowable loads have been increased for wind or earthquake load durations with no further increase allowed; reduce where other load durations govern.
  3. For dimensional information and required fasteners, refer to table above.
  4. For STHD14 1 1/2" End Distance in 8" stemwalls, loads can be increased to 4200 lbs.
  5. Allowable loads also apply to rim joist models.
  6. Testing to new ICC-ES acceptance criteria to be completed in 2009. Reference this web site for the latest loads and information.

next  top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
LSTHDSee specific model numbers for code listings.
LSTHD8          ER-5349
LSTHD8RJ          ER-5349
STHDSee specific model numbers for code listings.
STHD10          ER-5349 / ER-5275
STHD10RJ          ER-5349
STHD14          ER-5349 / ER-5275
STHD14RJ          ER-5349
STHD8          ER-5349 / ER-5275
STHD8RJ          ER-5349

top
Revit Drawings (2D & 3D Families):


next  topDrawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
Download the Simpson AutoCad Menu, which allows you to insert Ortho views directly into your AutoCAD drawing.

 ORTHOGRAPHIC
PERSPECTIVE
LSTHDNone for this model Post Tension Garage Footing: DWG | DXF
Post Tension Corner Install: DWG | DXF
Post Tension Top View: DWG | DXF
LSTHD8 LSTHD8: DWG | DXF
LSTHD8 front view: DWG | DXF
LSTHD8 left view: DWG | DXF
LSTHD8 right view: DWG | DXF
None for this model
LSTHD8RJNone for this model None for this model
STHDNone for this model High Wind-Resistant Construction D86: Holdowns: Typical STHD Installation: DWG | DXF
Floor to Floor Connections: DWG | DXF
Post Tension Garage Footing: DWG | DXF
Post Tension Corner Install: DWG | DXF
Post Tension Top View: DWG | DXF
STHD With Concrete Spalling: DWG | DXF
STHD Edge Installation: DWG | DXF
STHD10 STHD10: DWG | DXF
STHD10 front view: DWG | DXF
STHD10 right view: DWG | DXF
None for this model
STHD10RJ STHD10RJ: DWG | DXF
STHD10RJ front view: DWG | DXF
STHD10RJ right view: DWG | DXF
None for this model
STHD14 STHD14: DWG | DXF
STHD14 front view: DWG | DXF
STHD14 right view: DWG | DXF
None for this model
STHD14RJ STHD14RJ: DWG | DXF
STHD14RJ front view: DWG | DXF
STHD14RJ right view: DWG | DXF
High Wind-Resistant Construction D85: Holdowns: DWG | DXF
STHD14RJ: DWG | DXF
STHD8 STHD8: DWG | DXF
STHD8 front view: DWG | DXF
STHD8 right view: DWG | DXF
High Wind-Resistant Construction D52: Header to Wall Framing: DWG | DXF
STHD8RJ STHD8RJ: DWG | DXF
STHD8RJ front view: DWG | DXF
STHD8RJ right view: DWG | DXF
None for this model

   
top
Order free catalogs by mail
top top top
Fliers (PDFs):
top

Home | About Simpson Strong-Tie | Contact Simpson Strong-Tie | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson Strong-Tie newsletters

Copyright © 2010, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2010 Simpson Strong-Tie®