MASA/MASAP Mudsill Anchors


Installation

View step-by-step installation instructions

Mudsill anchors have always been a time-saving alternative to anchor bolts, and the new MASA anchors provide even greater load-carrying capacity than our original MAS. As a result, the MASA provides an alternative for 5/8" and 1/2" mudsill anchor bolts on 2x, double-2x and 3x mudsills. It also eliminates the need for 3" square plate washers for seismic design and, in some cases, has load capacities that meet or exceed the parallel and perpendicular to plate shear capacity of other cast-in-place anchors. Two versions of the MASA are available – the standard MASA for installation on standard forms and the MASAP for panelized forms.

The MASA and MASAP are code listed by ICC-ES under the 2006 and 2009 IBC® and IRC® and have been tested to meet the requirements of ICC-ES acceptance criteria AC-398 for cracked and uncracked concrete. New test data is reflected in the table below.

Material: 16 gauge

Finish: Galvanized, all available in ZMAX® coating. See Corrosion Information.

Installation:


top Gallery:
  roll over images below to see larger image
 
 
MASA MASAP Typical MASAP Installation in Concrete  
   
Typical MASA Installation in Concrete Typical MASA/MASAP Installation on Sill Plate
   

top Load Table:See code report listings below

These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.
Table
  1. Loads are based on allowable stress design (ASD) and include the load duration factor CD (with CD = 1.6) for wind/earthquake loading. No further increase is allowed. Reduce where other loads govern.
  2. Minimum concrete compression strength, f'c is 2500 psi.
  3. . Allowable loads are based on a minimum stemwall width of 6".
  4. For simultaneous loads in more than one direction, the connector must be evaluated using the Unity Equation.
  5. Per Section 1613 of the 2006 IBC, detached one- and two-family dwellings in SDC C may use the "Wind and SDC A&B" allowable loads.
  6. For designs under the 2006 IBC in SDC D-F, a 3x sill plate is required when the allowable design shearwall shear load is equal to or greater than 600 plf. If the allowable design shear load is greater than 350 plf but less than 600 plf, it is acceptable to use a 2x sill plate provided that the sill is anchored using double the number of MASA mudsill anchors required by design.
  7. For designs under the 2009 IBC, sill plate size shall comply with the shearwall requirements of the 2008 Special Design Provisions for Wind and Seismic. MASA spacing shall be as required for design load.
  8. MASA/MASAP may be installed using 7-nails (triangle holes not filled) when being used to replace a 1/2" diameter sill bolt for use on a 2x mudsill.
  9. Nails : 10dx1 1/2" = 0.148" dia. x 1 1/2" long. See other nail sizes and information.

topPrescriptive Spacing for MASA/MASAP to Replace Sill Anchor Bolts:

Table
  1. "Prescriptive" denotes designs per the IRC or conventional provisions of the IBC.
  2. Detached one- and two-family dwellings in SDC C may use the "Wind & SDC A&B" spacing.
  3. Spacing is based on the parallel to plate load direction only.
  4. 5/8" diameter AB required in SDC E.
  5. When replacing 1/2" sill bolts use 7-10dx1 1/2" nails (minimum nailing) and when replacing 5/8" sill bolts use 9-10dx1 1/2" nails (maximum nailing).
  6. Per Section 1613 of the 2006 IBC, detached one- and two-family dwellings in SDC C may use the "Wind and SDC A&B" allowable loads.
top Alternate Mudsill Anchor Installations:
  roll over images below to see larger image
 
Alternate Installation For Inside of Wall Continuity
Alternate Installation For Brick Ledges
 
Step 1:
Attach MASA 3 1/2" from inside of form. After concrete cures, remove nails and bend straps up 90°
Step 2:
Place mudsill on concrete and nail MAS/MASA over mudsill.
  Alternate MASA Installation for Brick Ledges
MASA/MASAP Rim Joist or Blocking
Installation in Concrete over Max. 1/2" Sheathing

next  top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
MASA  ESR-2555 / ESR-2523 * RR25851 FL13326      
MASAP  ESR-2555 / ESR-2523 * RR25851 FL13326      

* ESR-2523 is an Index of many of Simpson Strong-Tie Stamped and Welded Cold-formed Steel Products for Wood or Cold-formed Steel Construction



next  topDrawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
Download the Simpson Strong-Tie® AutoCAD® Menu, which allows you to insert Ortho views directly into your AutoCAD drawing.

 ORTHOGRAPHIC
PERSPECTIVE
MASA MASA: DWG | DXF
MASA front view: DWG | DXF
MASA left view: DWG | DXF
MASA right view: DWG | DXF
High Wind-Resistant Construction D50: Sill Plate to Foundation: DWG | DXF
MASA: DWG | DXF
MASAP MASAP: DWG | DXF
MASAP front view: DWG | DXF
MASAP left view: DWG | DXF
MASAP right view: DWG | DXF
MASAP: DWG | DXF

   
top
Order free catalogs by mail
top top top
Fliers (PDFs):
top

Home | About Simpson Strong-Tie | Contact Simpson Strong-Tie | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson Strong-Tie newsletters

Copyright © 2012, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2012 Simpson Strong-Tie®