META/HETA/HHETA/HETAL/TSS
Embedded Truss Anchors and Truss Seat Snap-in

  Print this page
Link to email this page to a friend  Email this page to a friend

The embedded truss anchor series provides an engineered method to properly attach roof trusses to concrete and masonry walls. The products are designed with staggered nail patterns for greater uplift resistance. Information regarding the use of two anchors on single- and multiple-ply trusses is included.

The TSS, a companion product of the META, provides a moisture barrier between the concrete and truss. The preassembled unit is riveted with no height adjustment.

Material: HHETA - 14 gauge; HETA - 16 gauge; HETAL strap - 16 gauge, truss seat - 18 gauge; META - 18 gauge; TSS - 22 gauge.

Finish: Galvanized. Some products available in ZMAX®; see Corrosion-Resistance.

Installation:


top Gallery:
  roll over images below to see larger image
 
META with TSS HETA20 (HHETA similar) HETAL
Typical HETA20
with TSS Installation
Typical META Installed with TSS Typical Installation with two METAs
Moisture barrier not shown (Typ.)

top Model Table:
Table

top Single Embedded Anchor Installation: See code report listings below
Table
  1. Loads include a 33% or 60% load duration increase on the fasteners for seismic or wind loading, but do not include a 33% stress increase on the steel capacity.
  2. Minimum f'c = 2500 psi. Minimum f'm = 1500 psi.
  3. For simultaneous loads in more than one direction, the connector must be evaluated as described in under Instructions to the Designer.
  4. Five nails must be installed into the truss seat of the HETAL.
  5. Parallel-to-wall load towards face of HETAL is 1975 lbs.
  6. It is acceptable to use a reduced number of fasteners provided that there is a reduction in uplift load capacity. See example. Lateral loads do not apply when fewer than 7 fasteners are used with the HETA and HHETA anchors or less than 6-16d or 7-10dx1 1/2" fasteners are used with the META anchor.
  7. The HHETA allowable F1 load can be increased to 435 lbs. if the strap is wrapped over the truss and a minimum of 12 nails are installed.
  8. Minimum spacing for multiple anchor installation is 2 times the embedment depth for full load. See Double Embedded Anchor Installation table for loads on closer spaced anchors.
  9. Single ply trusses may use either 10dx1 1/2" or 16d nails. 2 or 3 ply trusses shall use 16d nails.
  10. NAILS: 16d = 0.162" dia. x 3 1/2" long, 10dx1 1/2 = 0.148" dia. x 1 1/2" long. See other nail sizes and information.
top Double Embedded Anchor Installation: See code report listings below
Table
  1. Loads include a 33% or 60% load duration increase on the fasteners for seismic or wind loading, but do not include a 33% stress increase on the steel capacity.
  2. Minimum f'c = 2500 psi. Minimum f'm = 1500 psi.
  3. For simultaneous loads in more than one direction, the connector must be evaluated as described in Instructions to the Designer.
  4. Install with spoons facing outward and straps spaced no more than 1/8" wider than the truss width.
  5. Install half of the required number of fasteners in each strap.
  6. Lateral loads apply only to 2 or 3 ply applications with anchors spaced a minimum of 3" apart. For single ply applications use lateral loads from the Single Embedded Anchor Installation table.
  7. F1 lateral loads listed may cause an additional 1/16" deflection beyond the standard 1/8" limit where the
    straps are installed not wrapped over the heel as shown.
  8. Two HHETA anchors may be installed in a concrete tie beam on a 2 or 3 ply truss with 2 fewer nail for an allowable uplift load of 3040 lbs. (133) or 3050 lbs. (160).
  9. Single ply trusses may use either 10dx1 1/2" or 16d nails with allowable loads limited to the single ply column. 2 or 3 ply trusses shall use 16d nails.
  10. NAILS: 16d = 0.162" dia. x 3 1/2" long, 10dx1 1/2 = 0.148" dia. x 1 1/2" long. See other nail sizes and information.
top Code Reports (PDFs):
Legacy Reports
  ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
HETASee specific model numbers for code listings.
HETA12    FL1901 NER-469   ES-9603C
HETA16    FL1901 NER-469   ES-9603C
HETA20    FL1901 NER-469   ES-9603C
HETA20Z    FL1901 NER-469   ES-9603C
HETA24    FL1901      
HETA40    FL1901      
HETALSee specific model numbers for code listings.
HETAL12    FL1901 NER-469   ES-9603C
HETAL16    FL1901 NER-469   ES-9603C
HETAL20    FL1901 NER-469   ES-9603C
HETAL20Z    FL1901 NER-469   ES-9603C
HHETASee specific model numbers for code listings.
HHETA16    FL1901      
HHETA20    FL1901      
HHETA24    FL1901      
HHETA40    FL1901      
METASee specific model numbers for code listings.
META12    FL1901      
META14    FL1901      
META16    FL1901      
META18    FL1901      
META20    FL1901      
META20Z    FL1901      
META22    FL1901      
META24    FL1901      
META40    FL1901      
TSSNo load capacity: Products not submitted because they are not load rated and code approval is not required.
TSS-2 No code listing. Please contact us for test data.
TSS2-2 No code listing. Please contact us for test data.
TSS4 No code listing. Please contact us for test data.

   
top
Drawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
DWG
Perspective Orthographic DXF
Perspective Orthographic top
Order free catalogs by mail
top top top

Home | About Simpson | Contact Simpson | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson's newsletters

Copyright © 2008, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2008 Simpson Strong-Tie®