THA/THAC Adjustable Truss Hangers
for Plated Truss


The THA series have extra long straps that can be field-formed to give height adjustability and top flange hanger convenience. THA hangers can be installed as top flange or face mount hangers.

THA4x and THA2x-2 models feature a dense nail pattern in the straps, which provides more installation options and allows for easy top flange installation.

Material: See table.

Finish: Galvanized, some products available in ZMAX® coating. See Corrosion Information.

Installation:

The following installation methods may be used:

Options:


top Gallery:
 
THAC422 THA418 THA29 Typical THA29 Face Mount Installation
Typical THA422 Top Flange Installation on a 4x2 Floor Truss Typical THA29 Top Flange
Installation

Typical THA Top Flange Installation on a Nailer
(except THA29)

Alternate Installation of THA422

 
  roll over images below to see larger image
 
Double Shear Nailing Top View Double Shear Nailing Side View
Do not bend tab unless otherwise noted.
Dome Double Shear Nailing Side View (available on some models)
U.S. Patent 5,603,580

top Load Table:See code report listings below
Additional Corrosion Protection

These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.

Table
  1. Uplift has been increased 60% for wind or earthquake loading with no further increase allowed; reduce where other loads govern.
  2. Wind (160) is a download rating.
  3. For single 4x2 top chord carrying members or single 2x nailers, the following THA hangers can be installed using 10dx1 1/2" top nails and 2-16d face nails with reduced allowable loads as noted: THA418/THA422: 1415 lbs. for DF/SP, 1215 lbs. for SPF; THA426: 2245 lbs. for DF/SP, 1930 lbs. for SPF; THA422-2/THA426-2: 2345 lbs. for DF/SP, 2015 lbs. for SPF. Loads are based on hanger installations at panel points.
  4. Face mount installation loads are based on minimum of 2-ply 2x carrying member. For single 2x carrying members, use 10dx1 1/2" nails into the carrying member and tabulated fasteners into the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for 16 gauge and 14 gauge.
  5. Min. Top Flange refers to the minimum length of strap that must be field formed over the header.
  6. For the THA 2x models, one strap may be installed vertically according to the face mount nailing requirements and the other strap wrapped over the truss chord according to the top flange nailing requirements (see drawing above) and achieve full tabulated top flange installation downloads.
  7. NAILS: 16d = 0.162" dia. x 3 1/2" long, 10d = 0.148" dia. x 3" long. 10dx1 1/2" = 0.148" dia. x 1 1/2" long.
    See other nail sizes and information.
next  top Code Reports (PDFs):
Legacy Reports
  IAPMO UES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
THA213  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA218  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA218-2  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA222-2  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA29  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA413  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA418  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA422  ESR-2551 / ESR-2523 * RR25804 FL10447      
THA422-2No code listing: Please contact us for test data.
THA422Z  ESR-2551 / ESR-2523 *          
THA426      FL11468      
THA426-2No code listing: Please contact us for test data.
THAC418  ESR-2551 / ESR-2523 * RR25804 FL10447      
THAC422             
THAC422-2No code listing: Please contact us for test data.
THAC426 No code listing. Please contact us for test data.
THAC426-2 No code listing. Please contact us for test data.



next  topDrawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
Download the Simpson Strong-Tie® AutoCAD® Menu, which allows you to insert Ortho views directly into your AutoCAD drawing.

 ORTHOGRAPHIC
PERSPECTIVE
THA213 THA213: DWG | DXF
THA213 front view: DWG | DXF
THA213 left view: DWG | DXF
THA213 right view: DWG | DXF
THA213 top view: DWG | DXF
None for this model
THA218 THA218: DWG | DXF
THA218 front view: DWG | DXF
THA218 left view: DWG | DXF
THA218 right view: DWG | DXF
THA218 top view: DWG | DXF
Truss/Rafter to Masonry/Concrete Connectors: DWG | DXF
Truss/Rafter to Wood Top Plate 1: DWG | DXF
THA218-2 THA218-2: DWG | DXF
THA218-2 front view: DWG | DXF
THA218-2 left view: DWG | DXF
THA218-2 right view: DWG | DXF
THA218-2 top view: DWG | DXF
None for this model
THA222-2 THA222-2: DWG | DXF
THA222-2 front view: DWG | DXF
THA222-2 left view: DWG | DXF
THA222-2 right view: DWG | DXF
THA222-2 top view: DWG | DXF
High Wind-Resistant Construction D5: Girder/Truss to Wall Framing: DWG | DXF
Girder/Truss to Concrete Connections 1: DWG | DXF
THA29 THA29: DWG | DXF
THA29 front view: DWG | DXF
THA29 left view: DWG | DXF
THA29 right view: DWG | DXF
THA29 top view: DWG | DXF
THA29: DWG | DXF
THA413 THA413: DWG | DXF
THA413 front view: DWG | DXF
THA413 left view: DWG | DXF
THA413 right view: DWG | DXF
THA413 top view: DWG | DXF
None for this model
THA418 THA418: DWG | DXF
THA418 front view: DWG | DXF
THA418 left view: DWG | DXF
THA418 right view: DWG | DXF
THA418 top view: DWG | DXF
None for this model
THA422 THA422: DWG | DXF
THA422 front view: DWG | DXF
THA422 left view: DWG | DXF
THA422 right view: DWG | DXF
THA422 top view: DWG | DXF
None for this model
THA422-2 THA422-2: DWG | DXF
THA422-2 front view: DWG | DXF
THA422-2 left view: DWG | DXF
THA422-2 right view: DWG | DXF
THA422-2 top view: DWG | DXF
None for this model
THA422ZNone for this model None for this model
THA426 THA426: DWG | DXF
THA426 front view: DWG | DXF
THA426 left view: DWG | DXF
THA426 right view: DWG | DXF
THA426 top view: DWG | DXF
High Wind-Resistant Construction D51: Floor to Masonry/Concrete: DWG | DXF
THA426-2 THA426-2: DWG | DXF
THA426-2 front view: DWG | DXF
THA426-2 left view: DWG | DXF
THA426-2 right view: DWG | DXF
THA426-2 top view: DWG | DXF
None for this model
THAC418 THAC418: DWG | DXF
THAC418 front view: DWG | DXF
THAC418 left view: DWG | DXF
THAC418 right view: DWG | DXF
THAC418 top view: DWG | DXF
None for this model
THAC422 THAC422: DWG | DXF
THAC422 front view: DWG | DXF
THAC422 left view: DWG | DXF
THAC422 right view: DWG | DXF
THAC422 top view: DWG | DXF
None for this model
THAC422-2 THAC422-2: DWG | DXF
THAC422-2 front view: DWG | DXF
THAC422-2 left view: DWG | DXF
THAC422-2 right view: DWG | DXF
THAC422-2 top view: DWG | DXF
None for this model
THAC426 THAC426: DWG | DXF
THAC426 front view: DWG | DXF
THAC426 left view: DWG | DXF
THAC426 right view: DWG | DXF
THAC426 top view: DWG | DXF
None for this model
THAC426-2 THAC426-2: DWG | DXF
THAC426-2 front view: DWG | DXF
THAC426-2 left view: DWG | DXF
THAC426-2 right view: DWG | DXF
THAC426-2 top view: DWG | DXF
None for this model

   
top
Order free catalogs by mail
top top top top
Printed from
© 2013 Simpson Strong-Tie Company Inc.