The versatile THJA26 can accommodate right or left hand hips (at 45-degree skews), and can be installed before or after the hip and jack. Can also be used for double (terminal) hips.

Material: 14 gauge

Finish: Galvanized

Installation:

Options: These hangers cannot be modified.

top Gallery:
  roll over images below to see larger image
 
THJA26
U.S. Patent 5,253,465
Typical THJA26 Installation
Top View
Left Hand Hip Installation
Top View
Right Hand Hip Installation
Top View
Terminal Hip without Center Common Jack

top Load Table: See code report listings below
Table
  1. 16d sinkers (0.148" dia. x 3 1/4" long) may be substituted for the specified 16d commons at 0.85 of the table load.
  2. Combine hip and jack loads for total capacity (for terminal hip, add hip and jack loads then divide by two for each member).
  3. For a 2-2x4 bottom chord, multiply the down load by 0.50.
  4. Uplift loads have been increased 33% and 60% for earthquake or wind loading with no further increase allowed; reduce where
    other loads govern.
  5. Wind (133/160) is a download rating.
  6. Truss chord cross-grain tension may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T-ANSITPISP and
    T-ANSITPIDF for allowable loads that consider ANSI/TPI 1-2002 wood member design criteria.
  7. With single 2x carrying members, use 10dx1 1/2" nails and use 0.67 of the table value.
  8. Tabulated hip and jack allowable loads assume that 75% of the total load is distributed to the hip and 25% to the jack. It is permitted to distribute 65% to 85% of the tabulated total load to the hip, and the remaining percentage of total load to the jack. The combined hip and jack load may not exceed the published Total Load.
  9. NAILS: 16d = 0.162" dia. x 3 1/2" long, 10dx1 1/2 = 0.148" dia. x 1 1/2" long. See other nail sizes and information.
top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
THJA26  ESR-2554   FL474 NER-469 ER-5655  

   
top
Drawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
DWG
Perspective Orthographic DXF
Perspective Orthographic top
Order free catalogs by mail
top top top

Home | About Simpson | Contact Simpson | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson's newsletters

Copyright © 2008, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2008 Simpson Strong-Tie®