Hanger Options -
GLT/HGLT/GLS/HGLS/GLTV/HGLTV
See Hanger Options General Notes.
- Bevel cut the carried beam for skewed hangers.
- For hangers exceeding the joist height by 1/2", allowable load is 50% of the table roof load.
- GLT/GLTV/HGLT/HGLTV and GLS/HGLS series may be skewed to a maximum of 50° or sloped to a maximum of 45°.
- For skews greater than 15°, multiply the table uplift load by 0.50.
- For sloped only, the maximum allowable load is 6500 lbs. for the GLT/GLS/GLTV, 9165 lbs. for the HGLT/HGLS/HGLTV.
- For skewed only, the maximum allowable load is 6550 lbs. for the GLT/GLS/GLTV, 7,980 lbs. for the HGLT/HGLS/HGLTV. The deflection at full loading may reach 1/4".
- Sloped and skewed GLT/GLS/GLTV configurations have a maximum allowable load of 5500 lbs. Sloped and skewed combinations are not allowed for the HGLT/HGLS/HGLTV.
- Sloped and/or skewed seat hangers may not be installed in non-backed nailer/header installations.
- A top flange may be sloped down left or down right to 30° with or without a sloped and/or skewed seat (see illustration). Reduce allowable table loads using straight-line interpolation.
- The top flange may be offset left or right for placement at the end of a header. Minimum seat width 3 1/4". The maximum allowable load is 0.50 of the table roof load for the GLT/GLS/GLTV, and 0.45 for the HGLT/HGLS/HGLTV.
- For skewed and offset top flange hangers, the maximum allowable load is 3500 lbs.
- No uplift load.