See Hanger Options General Notes.
- HUTF can be skewed to a maximum of 45° or sloped to a maximum of 45°. HUTF can be skewed and sloped down only, provided W > 2 3/8". Hangers with a skew greater than 15° may have all the joist nailing on the outside angle. No skew with slope up options available.
- For the skewed-only HU34TF, HU24-2TF and HU44TF, the allowable loads are 0.50 of the table load. All other models have a maximum allowable load of 0.60 of the table loads.
- For skews greater than 15°, uplift loads are 0.75 of the table loads.
- For sloped and skewed hangers, the allowable loads are 0.70 of the table loads.
- For sloped down only hangers, allowable load is 0.78 of the table load.
- HUTF is available with one A flange concealed at 0.85 of the catalog table load. HUTF is also available with both flanges concealed provided the W dimension is 2 9/16" or greater, at 0.85 of the table load. Specify HUCTF for both flanges concealed. No skew options available.