www.strongtie.com


>>Home   > All Products - Alphabetical List    > Top Flange Hangers Load Tables

Top Flange Hangers Load Tables:
I-Joists & Structural Composite Lumber

  Print this page
Link to email this page to a friend  Email this page to a friend
  Code Reports
 
       
 
  All Top Flange Hanger Load Tables
 
  1. Loads may not be increased for short-term loading.
  2. Uplift loads are based on DF/SP lumber and have been increased 60% for wind or earthquake loading with no further increase allowed. For normal loading applications such as cantilever construction refer to Simpson Strong Tie® Connector Selector™ software or conservatively divide the uplift load by 1.6. For SPF/HF use 0.86 x DF/SP uplift load.
  3. WM loads listed are based on embedded installation (mid-wall) into a masonry block wall. (See W/WPU/WNP/WM/WMU/HW/HWU/GLT/HGLT)
  4. When I-joist is used as header, all nails must be 10dx1 1/2 and allowable loads assume flanges that are at least 1 1/2" thick made of Douglas Fir, LVL or LSL. For other flange thicknesses, apply load adjustment factors found in the table below.
  5. Hangers sorted in order of recommended selection for best overall performance and installation value.
  6. Other nail schedules and loads are listed on individual hanger pages: ITS/ITT/MIT/HIT, LBV/BA/B/HB and W/WP/WPU/WM/WMU/HW/HWU.
  7. See code reports.
  8. Web stiffeners are required where noted and when supporting double I-joists with flanges less than 1 5/16" thick.
  9. For 2 1/4"x22" and 24" joist sizes, refer to technical bulletin T-BSERIES08.
  10. NAILS: 16d and 16d DPLX = 0.162" dia. x 3 1/2" long, 10d = 0.148" dia. x 3" long, 10dx1 1/2= 0.148" dia. x 1 1/2" long. See other nail sizes and information.

Parallam® is a registered trademark of iLevel by Weyerhaeuser.


next  top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
BSee specific model numbers for code listings.
B3.56/14  ESR-1866 / ESR-2523 * RR25802 FL11166    
B3.56/16  ESR-1866 / ESR-2523 * RR25802 FL11166    
BANo code listing: Please contact us for test data.
BA3.56/14  ESR-1866 / ESR-2523 *   FL11166    
BA3.56/16  ESR-1866 / ESR-2523 *   FL11166    
GLTVSee specific model numbers for code listings.
GLTV3.514  ESR-2615 / ESR-2523 * RR25803 FL10667    
GLTV3.516  ESR-2615 / ESR-2523 * RR25803 FL10667    
GLTV3.518  ESR-2615 / ESR-2523 * RR25803 FL10667    
GLTV3.520  ESR-2615 / ESR-2523 * RR25803 FL10667    
GLTV3.56/18.75  ESR-2615 / ESR-2523 *        
HBNo code listing: Please contact us for test data.
HB3.56/14  ESR-1866 / ESR-2523 *   FL11166    
HB3.56/16  ESR-1866 / ESR-2523 *   FL11166    
HB3.56/18  ESR-1866 / ESR-2523 *   FL11166    
HB3.56/20  ESR-1866 / ESR-2523 *   FL11166    
HGLTVSee specific model numbers for code listings.
HGLTV3.514  ESR-2615 / ESR-2523 * RR25803 FL10667    
HGLTV3.516  ESR-2615 / ESR-2523 * RR25803 FL10667    
HGLTV3.518  ESR-2615 / ESR-2523 * RR25803 FL10667    
HGLTV3.520  ESR-2615 / ESR-2523 * RR25803 FL10667    
HGLTV3.56/18.75  ESR-2615 / ESR-2523 *        
HITSee specific model numbers for code listings.
HIT418  ESR-2615 / ESR-2523 * RR25803 FL10667    
HIT420  ESR-2615 / ESR-2523 * RR25803 FL10667    
HUINo code listing: Please contact us for test data.
HUI414TFNo code listing: Please contact us for test data.
HWINo code listing: Please contact us for test data.
HWI414  ESR-2615 / ESR-2523 * RR25803 FL10667    
HWI416  ESR-2615 / ESR-2523 * RR25803 FL10667    
HWI418  ESR-2615 / ESR-2523 * RR25803 FL10667    
HWI420  ESR-2615 / ESR-2523 * RR25803 FL10667    
HWUNo code listing: Please contact us for test data.
HWU3.56/14  ESR-2615 / ESR-2523 *   FL10667    
HWU3.56/16  ESR-2615 / ESR-2523 *   FL10667    
HWU3.56/18  ESR-2615 / ESR-2523 *   FL10667    
HWU3.56/20  ESR-2615 / ESR-2523 *   FL10667    
ITS3.56/14  ESR-2615 / ESR-2523 * RR25803 FL10667    
ITS3.56/16  ESR-2615 / ESR-2523 * RR25803 FL10667    
ITTSee specific model numbers for code listings.
ITT413  ESR-2615 / ESR-2523 * RR25803 FL10667    
ITT414  ESR-2615 / ESR-2523 * RR25803 FL10667    
ITT416  ESR-2615 / ESR-2523 * RR25803 FL10667    
ITTMSee specific model numbers for code listings.
ITTM414No code listing: Please contact us for test data.
ITTM416No code listing: Please contact us for test data.
LBVSee specific model numbers for code listings.
LBV3.56/13  ESR-1866 / ESR-2523 * RR25802 FL11166    
LBV3.56/14  ESR-1866 / ESR-2523 * RR25802 FL11166    
LBV3.56/16  ESR-1866 / ESR-2523 * RR25802 FL11166    
LBV3.56/18  ESR-1866 / ESR-2523 * RR25802 FL11166    
LBV3.56/20  ESR-1866 / ESR-2523 * RR25802 FL11166    
MITSee specific model numbers for code listings.
MIT414  ESR-2615 / ESR-2523 * RR25803 FL10667    
MIT416  ESR-2615 / ESR-2523 * RR25803 FL10667    
MIT418  ESR-2615 / ESR-2523 * RR25803 FL10667    
MIT420  ESR-2615 / ESR-2523 * RR25803 FL10667    
WMINo code listing: Please contact us for test data.
WMI414  ESR-2877 / ESR-2523 *        
WMI416  ESR-2877 / ESR-2523 *        
WMI418  ESR-2877 / ESR-2523 *        
WMI420  ESR-2877 / ESR-2523 *        
WPISee specific model numbers for code listings.
WPI414  ESR-2615 / ESR-2523 *   FL10667    
WPI416  ESR-2615 / ESR-2523 *   FL10667    
WPI418  ESR-2615 / ESR-2523 *   FL10667    
WPI420  ESR-2615 / ESR-2523 *   FL10667    
WPUSee specific model numbers for code listings.
WPU3.56/14  ESR-2615 / ESR-2523 *   FL10667    
WPU3.56/16  ESR-2615 / ESR-2523 *   FL10667    
WPU3.56/18  ESR-2615 / ESR-2523 *   FL10667    
WPU3.56/20  ESR-2615 / ESR-2523 *   FL10667    

* ESR-2523 is an Index of many of Simpson Strong-Tie Stamped and Welded Cold-formed Steel Products for Wood or Cold-formed Steel Construction



next  topDrawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
Download the Simpson AutoCad Menu, which allows you to insert Ortho views directly into your AutoCAD drawing.

 ORTHOGRAPHIC
PERSPECTIVE
B B with top flange sloped down left: DWG | DXF
B series front view: DWG | DXF
B series left view: DWG | DXF
B series right view: DWG | DXF
B series top view: DWG | DXF
B Hanger On I Beam: DWG | DXF
B3.56/14None for this model None for this model
B3.56/16None for this model None for this model
BANone for this model None for this model
BA3.56/14 BA3.56/14: DWG | DXF
BA3.56/14 front view: DWG | DXF
BA3.56/14 right view: DWG | DXF
BA3.56/14 top view: DWG | DXF
None for this model
BA3.56/16 BA3.56/16: DWG | DXF
BA3.56/16 front view: DWG | DXF
BA3.56/16 left vew: DWG | DXF
BA3.56/16 right view: DWG | DXF
BA3.56/16 top view: DWG | DXF
None for this model
GLTVNone for this model None for this model
GLTV3.514 GLTV3.514: DWG | DXF
GLTV3.514 front view: DWG | DXF
GLTV3.514 right view: DWG | DXF
GLTV3.514 top view: DWG | DXF
None for this model
GLTV3.516None for this model None for this model
GLTV3.518None for this model None for this model
GLTV3.520None for this model None for this model
GLTV3.56/18.75None for this model None for this model
HB HB series: DWG | DXF
HB series front view: DWG | DXF
HB series left view: DWG | DXF
HB series right view: DWG | DXF
HB series top view: DWG | DXF
HB: DWG | DXF
HB3.56/14None for this model None for this model
HB3.56/16None for this model None for this model
HB3.56/18None for this model None for this model
HB3.56/20None for this model None for this model
HGLTVNone for this model None for this model
HGLTV3.514 HGLTV3.514: DWG | DXF
HGLTV3.514 front view: DWG | DXF
HGLTV3.514 right view: DWG | DXF
HGLTV3.51 top view: DWG | DXF
None for this model
HGLTV3.516None for this model None for this model
HGLTV3.518None for this model None for this model
HGLTV3.520None for this model None for this model
HGLTV3.56/18.75None for this model None for this model
HITNone for this model None for this model
HIT418None for this model None for this model
HIT420None for this model None for this model
HUINone for this model None for this model
HUI414TFNone for this model None for this model
HWINone for this model None for this model
HWI414None for this model None for this model
HWI416None for this model None for this model
HWI418None for this model None for this model
HWI420None for this model None for this model
HWUNone for this model None for this model
HWU3.56/14 HWU3.56/14: DWG | DXF
HWU3.56/14 front view: DWG | DXF
HWU3.56/14 right view: DWG | DXF
HWU3.56/14 top view: DWG | DXF
None for this model
HWU3.56/16None for this model None for this model
HWU3.56/18None for this model None for this model
HWU3.56/20None for this model None for this model
ITS3.56/14None for this model None for this model
ITS3.56/16None for this model None for this model
ITT ITT series: DWG | DXF
ITT series front view: DWG | DXF
ITT series left view: DWG | DXF
ITT series right view: DWG | DXF
ITT series top view: DWG | DXF
ITT on I Beam with Nailer: DWG | DXF
Flush Framing: DWG | DXF
ITT: DWG | DXF
IUS/ITT Tab Installation 2: DWG | DXF
IUS/ITT Tab Installation 3: DWG | DXF
IUS/ITT Tab Installation 1: DWG | DXF
Web Stiffener 3: DWG | DXF
ITT413None for this model None for this model
ITT414None for this model None for this model
ITT416None for this model None for this model
ITTMNone for this model ITTM On Top of Block: DWG | DXF
ITTM In Grout Line: DWG | DXF
ITTM414None for this model None for this model
ITTM416None for this model None for this model
LBV LBV series: DWG | DXF
LBV series front view: DWG | DXF
LBV series left view: DWG | DXF
LBV series right view: DWG | DXF
LBV series top view: DWG | DXF
None for this model
LBV3.56/13None for this model None for this model
LBV3.56/14None for this model None for this model
LBV3.56/16None for this model None for this model
LBV3.56/18None for this model None for this model
LBV3.56/20None for this model None for this model
MIT MIT series: DWG | DXF
MIT series front view: DWG | DXF
MIT series left view: DWG | DXF
MIT series right view: DWG | DXF
MIT series top view: DWG | DXF
MIT: DWG | DXF
MIT Double LVL Installation: DWG | DXF
MIT414None for this model MIT414: DWG | DXF
MIT416None for this model None for this model
MIT418None for this model None for this model
MIT420None for this model None for this model
WMINone for this model None for this model
WMI414None for this model None for this model
WMI416None for this model None for this model
WMI418None for this model None for this model
WMI420None for this model None for this model
WPINone for this model None for this model
WPI414None for this model None for this model
WPI416None for this model None for this model
WPI418None for this model None for this model
WPI420None for this model None for this model
WPU WPU series: DWG | DXF
WPU skewed left and sloped down: DWG | DXF
WPU skewed left and sloped up: DWG | DXF
WPU skewed right and sloped down: DWG | DXF
WPU skewed right and sloped up: DWG | DXF
WPU sloped down: DWG | DXF
WPU sloped up: DWG | DXF
WPU series front view: DWG | DXF
WPU skewed left and sloped down front view: DWG | DXF
WPU skewed left and sloped up front view: DWG | DXF
WPU skewed right and sloped down front view: DWG | DXF
WPU skewed right and sloped up front view: DWG | DXF
WPU sloped down front view: DWG | DXF
WPU sloped up front view: DWG | DXF
WPU series left view: DWG | DXF
WPU sloped down left view: DWG | DXF
WPU sloped up left view: DWG | DXF
WPU series right view: DWG | DXF
WPU sloped down right view: DWG | DXF
WPU sloped up right view: DWG | DXF
WPU skewed left and sloped down top view: DWG | DXF
WPU skewed left and sloped up top view: DWG | DXF
WPU skewed right and sloped down top view: DWG | DXF
WPU skewed right and sloped up top view: DWG | DXF
WPU sloped down top view: DWG | DXF
WPU sloped up top view: DWG | DXF
WPU series top view: DWG | DXF
None for this model
WPU3.56/14 WPU3.56/14: DWG | DXF
WPU3.56/14 front view: DWG | DXF
WPU3.56/14 right view: DWG | DXF
WPU3.56/14 top view: DWG | DXF
None for this model
WPU3.56/16None for this model None for this model
WPU3.56/18None for this model None for this model
WPU3.56/20None for this model None for this model

   
top
Order free catalogs by mail
top top

Home | About Simpson Strong-Tie | Contact Simpson Strong-Tie | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson Strong-Tie newsletters

Copyright © 2010, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from