CBSDQ Sheathing-to-CFS Screw (Collated)

CBSDQ Sheathing-to-CFS Screw

This screw is used for securing sheathing to cold-formed steel (recommended thicknesses: 16 and 18 ga.).

Key Features

  • Ribbed flat head with nibs for easy countersinking
  • #2 undersized square drive (driver bit in each box; replacement bit model BIT2SU)
  • #2 drill point with wings
  • Quik Guard® coating
  • Curved collation

Applications

  • Sheathing to cold-formed steel (recommended thicknesses: 16 and 18 ga.)

Warning

  • Industry studies show that hardened fasteners can experience performance problems in wet or corrosive environments. Accordingly, use this product in dry, interior, and noncorrosive environments only.

Codes

  • City of Los Angeles RR25670
  • ASTM C1513 compliant
  • #8 screws meet minimum head diameter requirement per AISI S213-07, Lateral Design Standard

Related Links

Catalog Pages

Related Literature

Product Information Table

Model No. Length (in.) Screw Size Drive Type Head Diameter (in.) Head Type TPI Point Size Point Type Coating/Material Packaging Quantity Compatible Quik Drive® Tools UPC
CBSDQ158S 1 5/8 #8 #2 Square, Undersized 0.322 Ribbed Flat Head 18 2 Drill Point Quik Guard® Coating 1500 PRO200S, PRO250, PRO300S 746056333227
CBSDQ214S 2 1/4 #10 #2 Square, Undersized 0.322 Ribbed Flat Head 16 2 Drill Point Quik Guard® Coating 1000 PRO300S 746056644439
    These coated fasteners possess a level of corrosion resistance that makes them suitable for use in some exterior and corrosive environments and with some preservative-treated woods. For applications in higher-exposure applications, consider type-300 series stainless-steel fasteners for superior corrosion resistance. See additional important information before selecting a fastener for a specific application.

Load Tables

PPSD, CBSDQ, FHSD, WSFLRV Screw11 – Nominal Shear Strength (Rn) for Wind and Other In-Plane Loads for Shear Wall1,4,6 (lb./ft.)

  1. Nominal strength shall be multiplied by the resistance factor (Φ = 0.65) to determine the design strength or divided by the safety factor (Ω = 2.0) to determine the allowable strength.
  2. Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
  3. Where fully blocked gypsum board is applied to the opposite side of this assembly, per Table C2.1-2 AISI Standard North American Standard for Cold-Formed Steel Framing – Lateral Design 2007 Edition with Supplement No. 1 and Commentary with screw spacing at 7" (178 mm) o.c. edge and 7" (178 mm) o.c. field, these nominal strengths are permitted to be increased by 30%.
  4. For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
  5. Shear wall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
  1. For wood structural panel sheathed shear walls, tabulated Rn values shall be applicable for short-term load duration (wind loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AWC NDS, the values in the table above for wood structural panel sheathed shear walls shall be multipliedby 0.63 (normal) or 0.56 (permanent).
  2. Maximum stud spacing 24" o.c.
  3. All sheathing edges shall be attached to framing or 1 1/2" width 33 mil blocking.
  4. Table based on Table C2.1-1 AISI Standard North American Standard for Cold-Form Steel Framing – Lateral Design 2007 Edition with Supplement No. 1 and Commentary.
  5. See General Load Tables for screw strength.
  6. #8 screws — PPSD, CBSDQ, FHSD, WSFLRV. #10 screws — FHSD.
  7. Stud, track and blocking (if applicable) shall be a minimum of 33 mil.

PPSD, CBSDQ, FHSD, WSFLRV Screw12 – Nominal Shear Strength (Rn) for Seismic and Other In-Plane Loads for Shear Wall1,4,7 (lb./ft.)

  1. Nominal strength shall be multiplied by the resistance factor (φ = 0.60) to determine the design strength or divided by the safety factor (Ω = 2.5) to determine the allowable strength.
  2. Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
  3. Shear wall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
  4. For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
  5. Substitution of a stud or track of a different designation thickness is not permitted.
  1. Wall studs and track shall be of ASTM A1003 Structural Grade 33 (Grade 230) Type H steel for members with a designation thickness of 33 and 43 mil, and A1003 Structural Grade 50 (Grade 340) Type H steel for members with a designation thickness equal to greater than 54 mil.
  2. For wood structural panel sheathed shear walls, tabulated Rn values shall be applicable for short-term load duration (seismic loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above for wood structural panel sheathed shear walls shall be multiplied by 0.63 (normal) or 0.56 (permanent).
  3. Maximum stud spacing 24" o.c.
  4. All sheathing edges shall be attached to to framing or 1 1/2" width 33 mil blocking.
  5. Table based on Table C2.1-3 AISI Standard North American Standard for Cold-Form Steel Framing – Lateral Design 2007 Edition with Supplement No. 1 and Commentary.
  6. See General Load Tables for screw strength.
  7. #8 screws — PPSD, CBSDQ, FHSD, WSFLRV. #10 screws — FHSD.