Use this screw for wood or wood structural panel sheathing to cold-formed steel (recommended max. steel thickness: 3/16”).
Key Features
Flat head
Curved collation
Type 410 stainless-steel screw has nibs under the head for easy countersinking
2 1/2" length has wings on the shaft to prevent jacking of the wood panel during installation
Type 410 stainless steel is coated for additional corrosion protection
#3 square drive for #10 (replacement bit BIT3S)
#2 square drive for #8 (replacement bit BIT2S)
Applications
Wood or wood structural panel sheathing to cold-formed steel (recommended max. steel thickness: 3/16")
Ordering Information
These products are subject to quantities on hand or may require special ordering and are subject to minimum order quantities and longer lead times. Call Simpson Strong‑Tie for details (800) 999-5099.
Fastener Production Information and Stuff & Things
These products are subject to quantities on hand or may require special ordering and are subject to minimum order quantities and longer lead times. Call Simpson Strong‑Tie for details (800) 999-5099.
Model No.
Coating/Material
Screw Size
Length (in.)
Head Diameter (in.)
Drive Type
Head Type
TPI
Point Type
Point Size
Compatible Tools
Packaging Qty.
UPC
SSFHSD112S1016
Type 410 Stainless Steel
#10
1 1/2
0.382
#2 Square
Flat Head
16
Drill Point
3
Quik Drive® PROPP150G2
1000
707392746102
FHSD114S0818
Yellow-Zinc Coated
#8
1 1/4
0.310
#2 Square
Flat Head
18
Drill Point
2
Quik Drive® PRO200G2, Quik Drive® PRO200SG2
2500
746056000327
Product Information Table
Model No.
Length (in.)
Screw Size
Drive Type
Head Diameter (in.)
Head Type
TPI
Point Size
Point Type
Coating/Material
Packaging Quantity
Compatible Quik Drive® Tools
UPC
SSFHSD112S1016
1 1/2
#10
#2 Square
0.382
Flat Head
16
3
Drill Point
Type 410 Stainless Steel
1000
PROPP150
707392746102
FHSD114S0818
1 1/4
#8
#2 Square
0.310
Flat Head
18
2
Drill Point
Clear-Zinc Coating
2500
PRO200, PRO200S
746056000327
FHSD1S1018
1
#10
#2 Square
0.340
Flat Head
18
2
Drill Point
Yellow-Zinc Dichromate Coating
2500
PRO200S
746056665564
Load Tables
PPSD, CBSDQ, FHSD, WSFLRV Screw11 — Nominal Shear Strength (Rn) for Wind and Other In-Plane Loads for Shearwall (lb./ft.)
Nominal strength shall be multiplied by the resistance factor (Φ = 0.65) to determine the design strength or divided by the safety factor (Ω = 2.0) to determine the allowable strength.
Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
Where fully blocked gypsum board is applied to the opposite side of this assembly, per Table C2.1-2 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary with screw spacing at 7" (178 mm) o.c. edge and 7" (178 mm) o.c. field, these nominal strengths are permitted to be increased by 30%.
For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
Shearwall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
For wood structural panel sheathed shearwalls, tabulated Rn values shall be applicable for short-term load duration (wind loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AWC NDS, the values in the table above for wood structural panel sheathed shearwalls shall be multiplied by 0.63 (normal) or 0.56 (permanent).
Maximum stud spacing 24" o.c.
All sheathing edges shall be attached to framing or 1 1/2" width 33 mil blocking.
Table based on Table C2.1-1 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary.
Stud, track and blocking (if applicable) shall be a minimum of 33 mil.
PPSD, CBSDQ, FHSD, WSFLRV Screw12 — Nominal Shear Strength (Rn) for Seismic and Other In-Plane Loads for Shearwall (lb./ft.)
Nominal strength shall be multiplied by the resistance factor (Φ = 0.60) to determine the design strength or divided by the safety factor (Ω = 2.5) to determine the allowable strength.
Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
Shearwall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
Substitution of a stud or track of a different designation thickness is not permitted.
Wall studs and track shall be of ASTM A1003 Structural Grade 33 (Grade 230) Type H steel for members with a designation thickness of 33 and 43 mil, and A1003 Structural Grade 50 (Grade 340) Type H steel for members with a designation thickness equal to greater than 54 mil.
For wood structural panel sheathed shearwalls, tabulated Rn values shall be applicable for short-term load duration (seismic loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above for wood structural panel sheathed shearwalls shall be multiplied by 0.63 (normal) or 0.56 (permanent).
Maximum stud spacing 24" o.c.
All sheathing edges shall be attached to framing or 1 1/2" width 33 mil blocking.
Table based on Table C2.1-3 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary.