We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

FHSD Wood-to-CFS Screw (Collated)

Use this screw for wood or wood structural panel sheathing to cold-formed steel (recommended max. steel thickness: 3/16”).

Key Features

  • Flat head
  • Yellow zinc fasteners have curved collation; Type 410 have straight collation
  • Type 410 stainless-steel screw has nibs under the head for easy countersinking
  • Type 410 stainless steel is coated for additional corrosion protection
  • #3 square drive for #10 (replacement bit BIT3S)
  • #2 square drive for #8 (replacement bit BIT2S)

Applications

  • Wood or wood structural panel sheathing to cold-formed steel (recommended max. steel thickness: 3/16")

Ordering Information

  • These products are subject to quantities on hand or may require special ordering and are subject to minimum order quantities and longer lead times. Call Simpson Strong‑Tie for details (800) 999-5099.

Patent Information

  • US Patent 7,051,875

Related Links

Catalog Pages

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
These products are subject to quantities on hand or may require special ordering and are subject to minimum order quantities and longer lead times. Call Simpson Strong‑Tie for details (800) 999-5099.
Model No. Coating/Material Screw Size Length (in.) Head Diameter (in.) Drive Type Head Type TPI Max. Grip Length (in.) Point Type Point Size Compatible Tools Packaging Qty.
Footnotes
  1. These products are subject to quantities on hand or may require special ordering and are subject to minimum order quantities and longer lead times. Call Simpson Strong-Tie for details (800) 999-5099.
SSFHSD112S1016 Type 410 Stainless Steel #10 1 1/2 0.382 #2 Square Flat Head 16 1.313 Drill Point 3 Quik Drive® PROPP150G2 1000
FHSD114S0818 Yellow-Zinc Coated #8 1 1/4 0.310 #2 Square Flat Head 18 1.313 Drill Point 2 Quik Drive® PRO200G2, Quik Drive® PRO200SG2 2500

Product Information Table

Model No. Length (in.) Screw Size Drive Type Head Diameter (in.) Head Type TPI Point Size Point Type Coating/Material Packaging Quantity Compatible Quik Drive® Tools UPC
SSFHSD112S1016 1 1/2 #10 #2 Square 0.382 Flat Head 16 3 Drill Point Type 410 Stainless Steel 1000 PROPP150 707392746102
FHSD114S0818 1 1/4 #8 #2 Square 0.310 Flat Head 18 2 Drill Point Clear-Zinc Coating 2500 PRO200, PRO200S 746056000327
FHSD1S1018 1 #10 #2 Square 0.340 Flat Head 18 2 Drill Point Yellow-Zinc Dichromate Coating 2500 PRO200S 746056665564

Load Tables

PPSD, CBSDQ, FHSD, WSFLRV Screw11 — Nominal Shear Strength (Rn) for Wind and Other In-Plane Loads for Shearwall (lb./ft.)

  1. Nominal strength shall be multiplied by the resistance factor (Φ = 0.65) to determine the design strength or divided by the safety factor (Ω = 2.0) to determine the allowable strength.
  2. Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
  3. Where fully blocked gypsum board is applied to the opposite side of this assembly, per Table C2.1-2 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary with screw spacing at 7" (178 mm) o.c. edge and 7" (178 mm) o.c. field, these nominal strengths are permitted to be increased by 30%.
  4. For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
  5. Shearwall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
  6. For wood structural panel sheathed shearwalls, tabulated Rn values shall be applicable for short-term load duration (wind loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AWC NDS, the values in the table above for wood structural panel sheathed shearwalls shall be multiplied by 0.63 (normal) or 0.56 (permanent).
  7. Maximum stud spacing 24" o.c.
  8. All sheathing edges shall be attached to framing or 1 1/2" width 33 mil blocking.
  9. Table based on Table C2.1-1 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary.
  10. See General Load Table for screw strength.
  11. #8 screws — PPSD, CBSDQ, FHSD, WSFLRV. #10 screws — FHSD.
  12. Stud, track and blocking (if applicable) shall be a minimum of 33 mil.

PPSD, CBSDQ, FHSD, WSFLRV Screw12 — Nominal Shear Strength (Rn) for Seismic and Other In-Plane Loads for Shearwall (lb./ft.)

  1. Nominal strength shall be multiplied by the resistance factor (Φ = 0.60) to determine the design strength or divided by the safety factor (Ω = 2.5) to determine the allowable strength.
  2. Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
  3. Shearwall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
  4. For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
  5. Substitution of a stud or track of a different designation thickness is not permitted.
  6. Wall studs and track shall be of ASTM A1003 Structural Grade 33 (Grade 230) Type H steel for members with a designation thickness of 33 and 43 mil, and A1003 Structural Grade 50 (Grade 340) Type H steel for members with a designation thickness equal to greater than 54 mil.
  7. For wood structural panel sheathed shearwalls, tabulated Rn values shall be applicable for short-term load duration (seismic loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above for wood structural panel sheathed shearwalls shall be multiplied by 0.63 (normal) or 0.56 (permanent).
  8. Maximum stud spacing 24" o.c.
  9. All sheathing edges shall be attached to framing or 1 1/2" width 33 mil blocking.
  10. Table based on Table C2.1-3 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary.
  11. See General Load Table for screw strength.
  12. #8 screws — PPSD, CBSDQ, FHSD, WSFLRV. #10 screws — FHSD.

Code Reports & Compliance

Drawings