SURC/SULC Skewed U-Shaped Hanger (Right or Left), Concealed Flanges

Face-Mount Hangers for Engineered Wood

This product's information may differ depending on the category of use. You are currently viewing details related to Face-Mount Hangers for Engineered Wood. You can also view product information related to the category: Face-Mount Hangers for Solid Sawn Lumber

The SURC and SURLC are 45°-skewed hangers designed to support 2x and 4x members in wood construction. These U-shaped hangers feature concealed header flanges providing cleaner visible lines in exposed conditions. These are identical except that they are skewed 45° to the right (SURC) and the left (SULC), respectively.

Key Features

  • Features obround nail holes on the acute side, allowing nails to be easily installed parallel to the joist
  • These hangers cannot be modified but will accommodate a 40°- to 50°-skewed joist
  • A2 (acute) flange turned in to accommodate end-of-wall installation

Material

  • 16 gauge

Finish

  • Galvanized

Installation

  • Use all specified fasteners; see General Notes.
  • The joist end may be square cut or bevel cut.
  • Fill all round and obround nail holes with specified fasteners to achieve table loads. Where noted, triangle holes in the joist flange may be filled for additional uplift capacity.

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Skew L/R Ga. W (in.) H (in.) B (in.) Coating/Material Packaging Qty.
SULC210-2 Left 16 3 1/8 8 11/16 2 5/8 Zinc Galvanized, G90 1
SULC26-2 Left 16 3 1/8 4 15/16 2 5/8 Zinc Galvanized, G90 1
SULC410 Left 16 3 9/16 8 1/2 2 5/8 Zinc Galvanized, G90 1
SULC414 Left 16 3 9/16 12 1/2 2 5/8 Zinc Galvanized, G90 1
SULC46 Left 16 3 9/16 4 3/4 2 5/8 Zinc Galvanized, G90 1
SURC210-2 Right 16 3 1/8 8 11/16 2 5/8 Zinc Galvanized, G90 1
SURC26-2 Right 16 3 1/8 4 15/16 2 5/8 Zinc Galvanized, G90 1
SURC410 Right 16 3 9/16 8 1/2 2 5/8 Zinc Galvanized, G90 1
SURC414 Right 16 3 9/16 12 1/2 2 5/8 Zinc Galvanized, G90 1
SURC46 Right 16 3 9/16 4 3/4 2 5/8 Zinc Galvanized, G90 1

Load Tables

    Many of these products are approved for installation with Strong-Drive® SD Connector screws.

Actual Joist Size (in.) Model No. Dimensions (in.) Fasteners (in.) DF/SP Species Header Allowable Loads SPF/HF Species Header Allowable Loads
W H B A1 A2 Face Joist Uplift (160) Floor (100) Snow (115) Roof (125) Uplift (160) Floor (100) Snow (115) Roof
(125)
3 x 9-1/4 to 14 SUR/LC210-2 3 1/8 8 11/16 2 5/8 1 7/16 2 3/8 (14) 0.162 x 3 1/2 (6) 0.162 x 2 1/2 1,150 2,015 2,280 2,345 990 1,735 1,960 2,015
3-1/2 x 9-1/4 to 14 SUR/LC410 3 9/16 8 1/2 2 5/8 1 2 3/8 (14) 0.162 x 3 1/2 (6) 0.162 x 3 1/2 1,140 2,015 2,245 2,245 980 1,735 1,930 1,930
3-1/2 x 14 to 20 SUR/LC414 3 9/16 12 1/2 2 5/8 1 2 3/8 (18) 0.162 x 3 1/2 (8) 0.162 x 3 1/2 1,490 2,400 2,400 2,400 1,280 2,065 2,065 2,065
  1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern.
  2. Triangular nail holes may be filled with 0.148" x 1 1/2" nails for additional uplift (requires web stiffeners).
  3. When the supported member is an I-joist with flanges less than 1 5/16" thick, the allowable uplift shall not exceed 190 lb. without web stiffeners.
  4. Allowable downloads are based on a joist-bearing capacity of 750 psi.
  5. Fasteners: Nail dimensions in the table are listed diameter by length. For additional information, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.
Allowable Loads for SURC and SULC Model Hangers with SD Screws
Actual Joist Size Model No. Web Stiff Reqd Ga Dimensions DF/SP Allowable Loads (lbs) SD Screws SPF/HF Allowable Loads (lbs) SD Screws
W H B A1 A2 Face Face Uplift (100) Uplift2 (160) Floor (100) Snow (115) Roof (125) Wind (160) Uplift (100) Uplift2 (160) Floor (100) Snow (115) Roof (125) Wind (160)
3 x 9 1/4 -14 SUR/LC210-2 16 3 1/8 8 11/16 2 5/8 1 7/16 2 3/8 (14) SD9112 (6) SD9112 915 915 1835 1835 1835 1835 670 785 1570 1580 1580 1580
3 1/2 x 9 1/4 -14 SUR/LC410 16 3 9/16 8 15/32 2 5/8 1 2 3/8 (14) SD9112 (6) SD9112 915 915 1835 1835 1835 1835 670 785 1570 1580 1580 1580
3 1/2 x 14 -20 SUR/LC414 16 3 9/16 12 1/2 2 5/8 1 2 3/8 (18) SD9112 (8) SD9112 1200 1200 2430 2430 2430 2430 895 1030 2015 2090 2090 2090
  1. Uplift loads have been increased for wind or earthquake loading with no further increase allowed: reduce where other loads govern.
  2. Triangle nail holes may be filled (requires web stiffeners) with SD9112 screws for additional uplift
  3. When the supported member is an I-joist with flanges less than 1 5/16 inches thick, the allowable uplift shall not exceed 155 lbs. without web stiffeners.
  4. Allowable downloads are based on a joist bearing capacity of 750 psi for EWP.