This product's information may differ depending on the category of use. You are currently viewing details related to Face-Mount Hangers for Structural Composite Lumber. You can also view product information related to the categories of: Joist Framing Connectors for Cold-Formed Steel Construction, Face-Mount Hangers for Solid Sawn Lumber, Face-Mount Hangers for Glulam Beams, Face-Mount Masonry Hangers, Face-Mount Hangers for I-Joists

This heavy-duty, concealed-flange connector is designed for schools and other structures requiring additional strength, longevity and safety factors.

Material

  • 14 ga. (68 mil)

Finish

  • Galvanized

Installation

  • For attachment to wood use all specified fasteners in the allowable load tables; see General Notes.
  • Can be installed filling round holes only or filling round and triangle holes for maximum values.
  • Joists sloped up to 1/4:12 achieve table loads.
  • For attachment to steel members refer to technical bulletin T-C-HUHUC-W.
  • For attachment to masonry refer to technical bulletin T-C-HUHUCTTN.
    • These hangers are attached to grouted CMU walls using 1/4" x 2 3/4" hex-head Simpson Strong-Tie® Titen® screws or for concrete walls using 1/4" x 1 3/4" hex-head Titen screws. Titen screws are not provided.
    • Drill the 3/16"-diameter hole to the specified embedment depth plus 1/2".
    • Alternatively, drill the 3/16" diameter hole to the specified embedment depth and blow it clean using compressed air.
    • The hangers should be installed such that a minimum end and edge distance of 1 1/2" is maintained.
    • Provide moisture barrier between beam and wall per jurisdictional requirements.
    • Caution: Oversized holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity.
  • For attachment to cold-formed steel see Joist Framing Connectors for Cold-Formed Steel Construction, above.

Related Literature

Load Tables

See Face-Mount Hangers Load Table for Structural Composite Lumber.

Code Reports

Part IAPMO UES ER ICC-ES ESR City of Los Angeles State of Florida
HUC410 ESR-2549 ESR-2552 ESR-2523 RR25801 RR25807 FL10531 FL10655
HUC410-2 ESR-2552 ESR-2523 RR25801 FL10531
HUC412 ESR-2549 ESR-2552 ESR-2523 RR25801 FL10531 FL10655
HUC412-2 ESR-2552 ESR-2523 RR25801 FL10531
HUC414-2 ESR-2552 ESR-2523 RR25801 FL10531
HUC416 ESR-2549 ESR-2552 ESR-2523 RR25801 RR25807 FL10531 FL10655
HUC48 ESR-2549 ESR-2523 RR25807 FL10531 FL10655
HUC5.31/11 No code listing. Please contact us for test data.
HUC5.31/14 No code listing. Please contact us for test data.
HUC5.31/16 No code listing. Please contact us for test data.
HUC5.31/9 No code listing. Please contact us for test data.
HUC610 ESR-2549 ESR-2552 ESR-2523 RR25801 RR25807 FL10531 FL10655
HUC612 ESR-2549 ESR-2552 ESR-2523 RR25801 RR25807 FL10531 FL10655
HUC616 ESR-2549 ESR-2552 ESR-2523 RR25801 RR25807 FL10531 FL10655
HUC68 ESR-2549 ESR-2523 RR25807 FL10531 FL10655

ESR-2523 is an Index of many of Simpson Strong-Tie Stamped and Welded Cold-formed Steel Products for Wood or Cold-formed Steel Construction

Drawings

Part Orthographic Perspective
HUC410
HUC410
DWGDXF
HUC410 front view
DWG DXF
HUC410 left view
DWG DXF
HUC410 right view
DWG DXF
HUC410 top view
DWG DXF
None
HUC410-2None None
HUC412
HUC412
DWGDXF
HUC412 front view
DWG DXF
HUC412 left view
DWG DXF
HUC412 right view
DWG DXF
HUC412 top view
DWG DXF
None
HUC412-2None None
HUC414-2None None
HUC416None None
HUC48
HUC48
DWGDXF
HUC48 front view
DWG DXF
HUC48 left view
DWG DXF
HUC48 right view
DWG DXF
HUC48 top view
DWG DXF
None
HUC5.31/11None None
HUC5.31/14None None
HUC5.31/16None None
HUC5.31/9None None
HUC610
HUC610
DWGDXF
HUC610 front view
DWG DXF
HUC610 right view
DWG DXF
HUC610 top view
DWG DXF
None
HUC612
HUC612
DWGDXF
HUC612 front view
DWG DXF
HUC612 left view
DWG DXF
HUC612 right view
DWG DXF
HUC612 top view
DWG DXF
None
HUC616None None
HUC68
HUC68
DWGDXF
HUC68 front view
DWG DXF
HUC68 left view
DWG DXF
HUC68 right view
DWG DXF
HUC68 top view
DWG DXF
None