text.skipToContent text.skipToNavigation

LSU/LSSU/LSSUI Adjustable Rafter Hangers

LSU/LSSU/LSSUI

This series attaches joists or rafters to headers, sloped up or down, and skewed left or right, up to 45°.

Material

  • See table

Finish

  • Galvanized

Installation

  • Use all specified fasteners; see General Notes
  • Attach the sloped joist at both ends so that the horizontal force developed by the slope is fully supported by the supporting members
  • Web stiffeners required for I-joist applications
  • For additional information, see the installation video on this product in the online image gallery

Related Literature

Load Tables

    These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.

  1. Roof loads are 125% of floor loads unless limited by other criteria.
  2. Uplift loads include a 60% increase for wind or earthquake loading with no further increase is allowed; reduce where other loads govern.
  3. LSU3510-2, LSU4.12, LSU4.28 and LSU5.12 skew option must be factory-ordered.
  4. Minimum 11" joist height for LSU3510-2, LSU4.12, LSU5.12; 9 1/2" for all others.
  5. For skewed LSSU/LSSUI hangers, the inner most face fasteners on the acute angle side are not installed.
  6. Do not substitute 10d x 1 1/2" nails for face nails on slope and skew combinations or skewed only LSU, LSSU and LSSUI. See other nail sizes and information.
  7. Nails: 16d = 0.162" dia. x 3 1/2" long, 10d = 0.148" dia. x 3" long, 10d x 1 1/2" = 0.148" dia. x 1 1/2" long. See other nail sizes and information.

Code Reports

Part IAPMO UES ER ICC-ES ESR City of Los Angeles State of Florida
LSSU2.1No code listing: Please contact us for test data.
LSSU210 ESR-2551 ESR-2523 RR25804 FL10447
LSSU210-2 ESR-2551 ESR-2523 RR25804 FL10447
LSSU410 ESR-2551 ESR-2523 RR25804 FL10447
LSSUH310No code listing: Please contact us for test data.
LSSUI2.06No code listing: Please contact us for test data.
LSSUI25 ESR-2551 ESR-2523 RR25804 FL10447
LSSUI35 ESR-2551 ESR-2523 RR25804 FL10447
LSU3510-2No code listing: Please contact us for test data.
LSU4.12No code listing: Please contact us for test data.
LSU4.28No code listing: Please contact us for test data.
LSU5.12No code listing: Please contact us for test data.

ESR-2523 is an Index of many of Simpson Strong-Tie Stamped and Welded Cold-formed Steel Products for Wood or Cold-formed Steel Construction

Drawings

Part Orthographic Perspective
LSSU2.1
LSSU2.1
DWGDXF
LSSU2.1 front view
DWG DXF
LSSU2.1 left view
DWG DXF
LSSU2.1 right view
DWG DXF
None
LSSU210
LSSU210
DWGDXF
LSSU210 front view
DWG DXF
LSSU210 left view
DWG DXF
LSSU210 right view
DWG DXF
LSSU210 top view
DWG DXF
LSSU210
DWG DXF
LSSU210-2
LSSU210-2
DWGDXF
LSSU210-2 front view
DWG DXF
LSSU210-2 left view
DWG DXF
LSSU210-2 right view
DWG DXF
None
LSSU410
LSSU410
DWGDXF
LSSU410 front view
DWG DXF
LSSU410 left view
DWG DXF
LSSU410 right view
DWG DXF
None
LSSUH310
LSSUH310
DWGDXF
LSSUH310 front view
DWG DXF
LSSUH310 left view
DWG DXF
LSSUH310 right view
DWG DXF
None
LSSUI2.06None None
LSSUI25
LSSUI25
DWGDXF
LSSUI25 front view
DWG DXF
LSSUI25 left view
DWG DXF
LSSUI25 right view
DWG DXF
None
LSSUI35
LSSUI35
DWGDXF
LSSUI35 front view
DWG DXF
LSSUI35 left view
DWG DXF
LSSUI35 right view
DWG DXF
None
LSU3510-2None None
LSU4.12
LSU4.12
DWGDXF
LSU4.12 skewed left
DWGDXF
LSU4.12 skewed right
DWGDXF
LSU4.12 front view
DWG DXF
LSU4.12 skewed left front view
DWG DXF
LSU4.12 skewed right front view
DWG DXF
LSU4.12 left view
DWG DXF
LSU4.12 skewed right left view
DWG DXF
LSU4.12 right view
DWG DXF
LSU4.12 skewed left right view
DWG DXF
LSU4.12 skewed left top view
DWG DXF
LSU4.12 skewed right top view
DWG DXF
LSU4.12 top view
DWG DXF
LSU412
DWG DXF
LSU4.28None None
LSU5.12
LSU5.12
DWGDXF
LSU5.12 front view
DWG DXF
LSU5.12 right view
DWG DXF
LSU5.12 top view
DWG DXF
None