H/TSP Seismic and Hurricane Ties

H/TSP

Hurricane Ties for Plated Truss

This product's information may differ depending on the category of use. You are currently viewing details related to Hurricane Ties for Plated Truss. You can also view product information related to the category: Strong-Rod® URS Components

Simpson Strong-Tie® hurricane ties provide a positive connection between the truss/rafter and the wall of the structure to resist wind and seismic forces.

Material

  • See table

Finish

  • Galvanized. H7Z and H11Z — ZMAX® coating. Some models available in stainless steel or ZMAX. See Corrosion Information.

Installation

  • Use all specified fasteners; see General Notes.
  • H1 can be installed with flanges facing inward (reverse of "H1 Installation" drawing; see image gallery).
  • H2.5T, H3 and H6 ties are shipped in equal quantities of right and left versions (right versions shown).
  • Hurricane ties do not replace solid blocking.
  • When installing ties on plated trusses (on the side opposite the truss plate), do not fasten through the truss plate from behind. This can force the truss plate off of the truss and compromise truss performance.
  • H10A optional nailing to connect shear blocking: use 8d nails. Slots allow maximum field bending up to a pitch of 6:12; use H10A sloped loads for field-bent installation.

Considerations for Hurricane Tie Selection

  1. What is the uplift load?
  2. What is the parallel-to-plate load?
  3. What is the perpendicular-to-plate load?
  4. What is the species of wood used for the rafter and the top plates?
    (Select the load table based on the lowest-performing species of wood.)
  5. Will the hurricane tie be nailed into both top plates or the upper top plate only?
  6. What load or loads will the hurricane tie be taking?*
  7. Select hurricane tie based on performance, application, installed cost and ease of installation.

* When a connector is loaded simultaneously in more than one direction, the allowable load must be evaluated using option 1 or 2.

Option 1: Unity Equation

For all connectors use the following equation:

Design Uplift/Allowable Uplift + Design Lateral Parallel to Plate /
Allowable Lateral Parallel to Plate + Design Lateral Perpendicular
to Plate / Allowable Lateral Perpendicular to Plate < 1.0.

The three terms in the unity equation are due to the possible directions that exist to generate force on a connector. The number of terms that must be considered for simultaneous loading is at the sole discretion of the Designer and is dependent on their method of calculating wind forces and the utilization of the connector within the structural system.

Option 2: 75% Rule

As an alternative, certain roof-to-wall connectors (embedded truss anchors, seismic and hurricane ties [on this page], and twist straps) can be evaluated using the following: The design load in each direction shall not exceed the published allowable load in that direction multiplied by 0.75.

Related Links

Catalog Pages

Related Literature

Load Tables

Load Values with Carbon Steel Nails

    These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.

   These models are approved for installation with the Strong-Drive® SD Connector screw. See the load values below.

  1. Loads have been increased for wind or earthquake loading with no further increase allowed: reduce where other loads govern.
  2. Allowable loads are for one anchor. A minimum rafter thickness of 2 1/2" must be used when framing anchors are used on each side of the joist and on the same side of the plate (exeption: connectors installed such that nails on opposite side don't interfere).
  3. Allowable DF/SP uplift load for stud to bottom plate installation (see detail 15) is 390 lb. (H2.5A); 265 lb. (H2.5ASS); and 310 lb. (H8). For SPF/HF values multiply these values by 0.86.
  4. Allowable loads in the F1 direction are not intended to replace diaphragm boundry members or cross-grain bending of the truss or rafter members.
  5. When cross-grain bending or cross-grain tension cannot be avoided in the members, mechanical reinforcement to resist such forces may be considered.
  6. Hurricane Ties are shown on the outside of the wall for clarity and assume a minimum overhang of 3 1/2". Installation on the inside of the wall is acceptable (see General Instructions for the Installer notes s). For uplift continuous load path, connections in the same area (i.e. truss to plate connector and plate to stud connector) must be on the same side of the wall. See T-HTIEBEARING for more information.
  7. Southern Pine allowable uplift loads for H10A = 1,340 lb. and for the H14 = 1,465 lb.
  8. Refer to technical bulletin T-HTIEBEARING for allowable bearing enhancement loads.
  9. H10S can have the stud offset a maximum of 1" from rafter (center to center) for a reduced uplift of 890 lb. (DF/SP) and 765 lb. (SPF).
  10. H10S nails to plates are optional for uplift but required for lateral loads.
  11. Some load values for the stainless-steel connectors shown here are lower than those for the carbon-steel versions. Ongoing test programs have shown this to also be the case with other stainless-steel connectors in the product line that are installed with nails. See General Corrosion Risks for updated information.
  12. The allowable loads of stainless-steel connectors match carbon-steel connectors when installed with Simpson Strong-Tie stainless-steel, SCNR ring-shank nails. For more information, refer to engineering letter L-F-SSNAILS.
  13. Allowable DF/SP/SPF uplift load for the H2.5A fastened to a 2x4 truss bottom chord and double top plates using (5) 8d x 1 1/2" nails into the top plates and (3) 8d x 1 1/2" nails into the lowest three flange holes into the truss bottom chord is 260 lb. (160).
  14. Nails: 16d x 2 1/2" = 0.162" dia. x 2 1/2" long, 10d = 0.148" dia. x 3" long, 10d x 1 1/2" = 0.148" dia. x 1 1/2" long, 8d = 0.131" dia. x 2 1/2" long, 8d x 1 1/2" = 0.131" dia. x 1 1/2" long.
    See other nail sizes and information.
  15. Screws: Strong-Drive® SD #9 x 1 1/2" (model SD9112) = 0.131" dia. x 1 1/2" long (for the models marked with the orange flag only). Full table loads apply.
Load Values with Stainless Steel Nails
Model No. Fasteners DF/SP Allowable Loads Upliftwith8d x 1 1/2"Nails (160) SPF/HF Allowable Loads Upliftwith8d x 1 1/2"Nails (160)
To Rafters/ Truss To Plates To Studs Uplift Lateral (160) Uplift Lateral (160)
(160) F1 F2 (160) F1 F2
  1. H10ASS uplift load for southern pine with SSNA10 nails is 1340 lbs.
  2. SSNA8, SSA8d, SSNA10 nails are Simpson Strong-Tie® stainless steel ring shank nails.
  3. NAILS: SSN8 and SSNA8 = 0.131" dia. X 1 1/2" long. SSN10 and SSNA10 = 0.148" dia. X 1 1/2" long. SSA8d = 0.131" dia. x 2 1/2" long. See other nail sizes and information.
H2ASS 5-SSN8 2-SSN8 5-SSN8 400 130 55 - 345 130 55 -
5-SSNA8 2-SSNA8 5-SSNA8 575 130 55 - 495 130 55 -
H2.5ASS 5-SS8d 5-SS8d - 440 75 70 365 380 75 70 310
5-SSA8d 5-SSA8d - 600 110 110 575 535 110 110 495
H3SS 4-SS8d 4-SS8d - 280 145 120 275 225 100 85 210
4-SSA8d 4-SSA8d - 455 125 160 415 320 105 140 290
H8SS 5-SSN10 5-SSN10 - 610 90 120 440 370 90 55 335
5-SSNA10 5-SSNA10 - 745 75 - 630 565 75 - 510
H10ASS 9-SSN10 9-SSN10 - 970 565 195 - 835 485 170 -
9-SSNA10 9-SSNA10 - 1140 1 590 285 - 1015 505 285 -
Load Values with Strong-Drive® SD Connector Screws
Model No. Fasteners DF/SP Allowable Loads SPF/HF Allowable Loads
To Rafters/ Truss To Plates/ Base To Studs/ Post Uplift Lateral Uplift Lateral
(160) F1 (160) F2 (160) (160) F1 (160) F2 (160)

    These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.

  1. H connector loads based on installation to double top plate.
  2. Uplift load for the H8 stud to bottom plate installation is 380 lbs for DF/SP and 325 lbs for SPF/HF.
H1 6-SD9112 4-SD9112 - 505 600 390 435 515 335
H2.5 5-SD9112 5-SD9112 - 480 305 165 410 265 145
H2.5A 5-SD9112 5-SD9112 - 625 450 110 540 385 95
H8 5-SD9112 5-SD9112 - 820 85 - 705 75 -
H10 8-SD9112 8-SD9112 - 1135 840 325 975 720 280

Code Reports

Part IAPMO UES ER ICC-ES ESR City of Los Angeles State of Florida
HSee specific model numbers for code listings.
H1 ESR-2613 ESR-2523 ESR-3096 RR25718 RR25910 FL10456
H10 ESR-3096 RR25910 FL10456
H10A ER-102 ER-112 ESR-2613 ESR-2523 RR25718 RR25814 FL10446 FL10456
H10A-2 ER-102 ER-112 RR25814 FL10446
H10AR No code listing. Please contact us for test data.
H10ASS No code listing. Please contact us for test data.
H10R No code listing. Please contact us for test data.
H10SSNo code listing: Please contact us for test data.
H10Z ESR-2613 ESR-2523 ESR-3096 RR25910 FL10456
H11 No code listing. Please contact us for test data.
H11ZNo code listing: Please contact us for test data.
H14 ER-102 ER-112 RR25814 FL10446
H15 FL10456
H15-2 FL10456
H16 FL11470
H16-2 FL11470
H16-2S FL11470
H16S FL11470
H1Z ESR-2613 ESR-2523 RR25718 FL10456
H2 RR25718 FL10456
H2.5 ESR-3096 RR25718 RR25910 FL10456
H2.5A ESR-2613 ESR-2523 ESR-3096 RR25910 RR25718 FL10456
H2.5ASSNo code listing: Please contact us for test data.
H2.5AZ ESR-2613 ESR-2523 ESR-3096 RR25910 RR25718 FL10456
H2.5SSNo code listing: Please contact us for test data.
H2.5T ER-102 ER-112 RR25814 FL10446
H2.5Z ESR-2613 ESR-2523 RR25718 FL10456
H2A ER-102 ER-112 RR25814 FL10446
H2ASS No code listing. Please contact us for test data.
H2SSNo code listing: Please contact us for test data.
H2Z ESR-2613 ESR-2523 RR25718 FL10456
H3 ESR-2613 ESR-2523 RR25718 FL10456
H3SSNo code listing: Please contact us for test data.
H3Z ESR-2613 ESR-2523 RR25718 FL10456
H6 ESR-2613 ESR-2523 RR25718 FL10456
H6Z ESR-2613 ESR-2523 RR25718 FL10456
H7 No code listing. Please contact us for test data.
H7Z ESR-2613 ESR-2523 RR25718 FL10456
H8 ER-102 ER-112 ESR-3096 RR25814 RR25910 FL10446 FL11470
H8SS No code listing. Please contact us for test data.
H8Z ER-102 ER-112 ESR-3096 RR25814 RR25910 FL10446 FL11470
H9KTNo code listing: Please contact us for test data.
HGA10 ER-102 ER-112 RR25814
HGA10KT ER-102 ER-112 RR25814 FL10446 FL11478
HS24 ESR-2613 ESR-2523 RR25718 FL10456
TSP ER-102 ER-124 RR25489 FL11470 FL13872

ESR-2523 is an Index of many of Simpson Strong-Tie Stamped and Welded Cold-formed Steel Products for Wood or Cold-formed Steel Construction

Drawings

Part Orthographic Perspective
H1
H1 Front View
DWG DXF
H1 Left View
DWG DXF
H1 Right View
DWG DXF
H1 Top View
DWG DXF
AC4-H1 Installed Perspective View
DWG DXF
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D129: Overlapping Connectors - HWRC D129 Overlapping Connectors
DWG DXF
H1 Installed Perspective View
DWG DXF
H10None
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
H10A
H10A Front View
DWG DXF
H10A Left View
DWG DXF
H10A Right View
DWG DXF
H10A Top View
DWG DXF
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D129: Overlapping Connectors - HWRC D129 Overlapping Connectors
DWG DXF
H10A-2None
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D129: Overlapping Connectors - HWRC D129 Overlapping Connectors
DWG DXF
High Wind Resistant Construction Detail D2: Truss/Rafter to Wood Double Top Plates - HWRC D2 TrussRafter to Wood Double Top Plates
DWG DXF
H10ARNone
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D129: Overlapping Connectors - HWRC D129 Overlapping Connectors
DWG DXF
H10RNone
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
H11None None
H14
H14 Front View
DWG DXF
H14 Left View
DWG DXF
H14 Right View
DWG DXF
H14 Top View
DWG DXF
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D129: Overlapping Connectors - HWRC D129 Overlapping Connectors
DWG DXF
H15None
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
H15-2None None
H16None
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D20: Post-Installed Truss/Rafter to Masonry/Concrete - HWRC D20 Post Installed TrussRafter to MasonryConcrete
DWG DXF
H16 Installed Perspective View
DWG DXF
H16in Installed Perspective View
DWG DXF
High Wind Resistant Construction Detail D34: Truss/Rafter to Single Top Plate - HWRC D34 TrussRafter to Single Top Plate
DWG DXF
H16-2None
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
H16-2 Installed Perspective View
DWG DXF
H16in Installed Perspective View
DWG DXF
H16-2SNone
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
H16in Installed Perspective View
DWG DXF
H16SNone
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
H16in Installed Perspective View
DWG DXF
H16S Installed on Concrete Wall Perspective View
DWG DXF
H2None None
H2.5
H2.5 Front View
DWG DXF
H2.5 Left View
DWG DXF
H2.5 Right View
DWG DXF
H2.5 Top View
DWG DXF
H2.5 Installed Perspective View
DWG DXF
H2.5A
H2.5A Front View
DWG DXF
H2.5A Left View
DWG DXF
H2.5A Right View
DWG DXF
H2.5A Top View
DWG DXF
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D24: Truss/Rafter Hip to Wall - HWRC D24 TrussRafter Hip to Wall
DWG DXF
High Wind Resistant Construction Detail D4: Truss/Rafter to Wood Double Top Plates - HWRC D4 TrussRafter to Wood Double Top Plates
DWG DXF
High Wind Resistant Construction Detail D5: Girder/Truss to Wood Wall Framing - HWRC D5 GirderTruss to Wood Wall Framing
DWG DXF
H2.5A Installed Perspective View
DWG DXF
High Wind Resistant Construction Detail D34: Truss/Rafter to Single Top Plate - HWRC D34 TrussRafter to Single Top Plate
DWG DXF
High Wind Resistant Construction Detail D43: Top Plates to Stud - HWRC D43 Top Plates to Stud
DWG DXF
High Wind Resistant Construction Detail D35: Truss/Rafter to Single Top Plate - HWRC D35 TrussRafter to Single Top Plate
DWG DXF
High Wind Resistant Construction Detail D59: Header to Wall Framing - HWRC D59 Header to Wall Framing
DWG DXF
High Wind Resistant Construction Detail D115: Strong-Rod™ Uplift Restraint System - HWRC D115 Uplift Rod System
DWG DXF
H2.5T
H2.5T Front View
DWG DXF
H2.5T Left View
DWG DXF
H2.5T Right View
DWG DXF
H2.5T Top View
DWG DXF
High Wind Resistant Construction Detail D126: Achieve Twice the Load - HWRC D126 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D127: Achieve Twice the Load - HWRC D127 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D128: Achieve Twice the Load - HWRC D128 H Tie installations for Twice the load
DWG DXF
High Wind Resistant Construction Detail D3: Truss/Rafter to Wood Double Top Plates - HWRC D3 TrussRafter to Wood Double Top Plates
DWG DXF
H2.5T Installed Perspective View - Rafter
DWG DXF
H2.5T Installed Perspective View - Truss
DWG DXF
H2A
H2A Front View
DWG DXF
H2A Left View
DWG DXF
H2A Right View
DWG DXF
H2A Top View
DWG DXF
High Wind Resistant Construction Detail D130: Overlapping Connectors - HWRC D130 Load Path Installation Considerations Overlapping Connectors
DWG DXF
High Wind Resistant Construction Detail D40: Truss/Rafter Directly to Stud - HWRC D40 TrussRafter directly to stud
DWG DXF
H3
H3 Front View
DWG DXF
H3 Left View
DWG DXF
H3 Right View
DWG DXF
H3 Top View
DWG DXF
H3 Installed Perspective View
DWG DXF
High Wind Resistant Construction Detail D34: Truss/Rafter to Single Top Plate - HWRC D34 TrussRafter to Single Top Plate
DWG DXF
High Wind Resistant Construction Detail D35: Truss/Rafter to Single Top Plate - HWRC D35 TrussRafter to Single Top Plate
DWG DXF
H6
H6 Front View
DWG DXF
H6 Left View
DWG DXF
H6 Right View
DWG DXF
H6 Top View
DWG DXF
H6 Installed Perspective View
DWG DXF
H6-in Installed Perspective View
DWG DXF
H7None None
H8
H8 Front View
DWG DXF
H8 Left View
DWG DXF
H8 Right View
DWG DXF
H8 Top View
DWG DXF
High Wind Resistant Construction Detail D11: I-Joists to Wall Framing - HWRC D11 I Joist
DWG DXF
High Wind Resistant Construction Detail D4: Truss/Rafter to Wood Double Top Plates - HWRC D4 TrussRafter to Wood Double Top Plates
DWG DXF
H8 Installed Perspective View - Hip Valley Truss
DWG DXF
H8 Installed Perspective View - Plate to I Joist
DWG DXF
H8 Installed Perspective View - Plate to Joist
DWG DXF
H8 Installed Perspective View - Plate to Stud
DWG DXF
H8 Installed Perspective View - Rim Joist to PlateStud
DWG DXF
High Wind Resistant Construction Detail D43: Top Plates to Stud - HWRC D43 Top Plates to Stud
DWG DXF
H9KTNone None
HGA10None None
HGA10KT
HGA10KT Front View
DWG DXF
HGA10KT Right View
DWG DXF
HGA10KT Top View
DWG DXF
High Wind Resistant Construction Detail D116: Gable End to Wall Framing - HWRC D116 Gable End to Wall Framing
DWG DXF
High Wind Resistant Construction Detail D118: Gable End to Wall Framing - HWRC D118 Gable End to Wall Framing
DWG DXF
HGA10KT Installed Perspective View
DWG DXF
HGA10KT Installed Perspective View - Rim Joist
DWG DXF
High Wind Resistant Construction Detail D35: Truss/Rafter to Single Top Plate - HWRC D35 TrussRafter to Single Top Plate
DWG DXF
HS24None
HS24 Installed Perspective View
DWG DXF
TSPNone
High Wind Resistant Construction Detail D129: Overlapping Connectors - HWRC D129 Overlapping Connectors
DWG DXF
High Wind Resistant Construction Detail D132: Overlapping Connectors - HWRC D132 Load Path Installation Considerations Overlapping Connectors
DWG DXF
High Wind Resistant Construction Detail D4: Truss/Rafter to Wood Double Top Plates - HWRC D4 TrussRafter to Wood Double Top Plates
DWG DXF
High Wind Resistant Construction Detail D41: Top Plates to Stud - HWRC D41 Top Plates to Stud
DWG DXF